Multiple Multiswitch Installation
If you need to connect more than four IRDs to the TracVision
antenna, you may carry out a multiple multiswitch installation,
as shown in Figure 2-11.
DC Power
DC In
RHCP
VHF/UHF
+13v
Multiswitch
Out 1
Out 2
Out 3
IRD #1
IRD #2
IRD #3
Connecting the IRD Ground Wire
A grounding wire has been provided to connect your IRD to a
suitable ground. Attach the grounding wire to any suitable screw
on the rear panel of the IRD with a good contact with the IRD
chassis. The other end should be connected to a suitable DC
ground, ideally to the switchplate's ground terminal (route the
ground wire through the switchplate panel cutout and leave
unconnected for now). Each IRD that you connect to the
TracVision system should have a similar ground connection.
If you are using a multiswitch, you can ground the multiswitch instead
of the individual IRDs.
54-0150
TracVision Antenna Baseplate
RF1
RF2
RF Splitters/
Power Dividers
LHCP
+18v
DC Power
Out 4
IRD #4
DC In
Out 1
IRD #5
IRD #6
Figure 2-11
Multiple Multiswitch Installation
Power
(North American systems only)
Data
RHCP
VHF/UHF
LHCP
+13v
+18v
Multiswitch
Out 2
Out 3
Out 4
IRD #7
IRD #8
Be sure to connect a ground cable
from each IRD to a suitable DC
ground, ideally the switchplate's
ground terminal.