Part Names - York HTCA Installation Manual

Mini-split air conditioner
Table of Contents

Advertisement

PART NAMES

INDOOR UNIT
3
Air inlet
4
5
OUTDOOR UNIT
Air inlet
DISPLAY PANEL
NOTE
The display panel on the indoor unit would look like
one of following:
Model 12-21
TIMER OPERATION
PRE-DEF
Cooling/Heating
Model 24-36
OPERATION AUTO
Cooling Only
OPERATION AUTO
4
ENGLISH
J435.indd 4
2
1
8
6
7
Air outlet
10
9
Air outlet
Infrared signal receptor
Infrared signal receptor
OPERATION AUTO
TIMER
ECON
PRE-DEF
TIMER
PRE-DEF.
TIMER
INDOOR UNIT
1
Front panel frame
2
Front panel
3
Air filter
4
Horizontal air flow grille
5
Vertical air flow louver
6
Room temperature sensor
7
Display panel
-
Active Carbon
Electrostatic Fiber Filter (Standard)
DISPLAY PANEL
OPERATION Indicator: The indicator flashes once every sec
ond after power is on and illuminates when the air connditioner
is in operation.
TIMER Indicator: The indicator illuminates when TIMER is
set ON.
PRE-DEF. Indicator(For cooling & heating model only): The
air conditioner starts defrosting automatically if outdoor unit
frosts in heating operating. At this time, PRE.-DEF. Indicator
illuminates.
AUTO Indicator: This indicator flashes when the air conditioner
is in AUTO operation.
11
ECON Indicator: This indicator illuminates while the air
conditioner is in economic operation.
12
NOTE
All the pictures in this manual are for explanation purpose only.
T
h
y e
m
y a
b
e
s
g i l
h
purchased. The actual shape shall prevail.
OPERATING TEMPERATURE
Mode
Temperature
Room temperature
Outdoor
temperature
CAUTIONS
1. If air conditioner is used outside of the above conditions,
certain safety protection features may come into operation
cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner
operates in excess of this figure, the surface of the air conditioner
may attract condensation. Please set the vertical air flow
louver to its maximum angle (Vertically to the floor), and set
HIGH fan mode.
3. Optimum performance will be achieved within these operating
temperature.
8
Infrared signal receiver
9
Remote controller
10
Drain hose, refrigerant
connecting pipe
11
Connective cable
12
Stop valve
y l t
d
f i
e f
e r
n
f t
o r
m
h t
e
a
r i
Cooling
Heating
operation
operation
17°C-32°C
0°C-30°C
18°C-43°C
(-5°C-43°C:For the
models with low
temperature
-7°C-24°C
cooling system)
21°C-52°C
(For special
tropical Models)
-
c
o
n
d
t i
o i
n
r e
y
o
u
Drying
operation
17°C-32°C
11°C-43°C
21°C-52°C
(For special
tropical
Models)
1/22/08 11:13:47 AM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents