Page 1
The Briarwood The Briarwood The Briarwood The Briarwood Blaze King Blaze King Blaze King Blaze King Model Model Model Model BRII/90 BRII/90 BRII/90 BRII/90 Solid Fuel Solid Fuel Solid Fuel Solid Fuel Heater Heater Heater Heater Residential Residential Residential Residential...
Page 2
To Our Valued Customers To Our Valued Customers Dear Customer: Thank you for purchasing the BRIARWOOD II, wood burning stove (hereafter referred to as "stove"). This owner's manual explains the steps required to safely assemble, install, operate, and maintain your new stove. Be a responsible stove owner; PLEASE CAREFULLY READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW STOVE.
Accessories—Installation—Fan Kit and Rear Shield ..........15 CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURN. READ NAMEPLATE AND INSTRUCTIONS BEFORE OPERATING THE HEATER. Rev. Date: January 12, 2004 Page 3 Printed: February 8, 2005 OM-BRII/90.PUB...
Also for use in MOBILE HOMES MODEL: BRII/90 Tested to : UL1482-1998 / ULC S627-M93 CERTIFIED IN BOTH UNITED STATES AND CANADA PREVENT HOUSE FIRES- Install and use only in accordance with Blaze King’s installation and operation instructions. Contact local building or fire officials about restrictions and installation inspection in your area.
July 1, 1990. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 10,600 - 36,000 BTU/Hr. We strongly recommend that you hire a licensed installer to properly install your Briarwood stove. In the USA technicians are certified by the HPA, in Canada technicians are certified by WETT.
Page 7
NFPA is: 470 Atlantic Avenue, Boston, MA 02210. 24. For further information, refer to NFPA 211. 25. Do not over fire your woodstove. Although the Briarwood II is designed to heat efficiently, it should never be fired to a red-hot condition.
After a severe chimney fire, the complete chimney system and connecting pipes must be checked by a qualified person before further use. Rev. Date: January 12, 2004 Page 8 Printed: February 8, 2005 OM-BRII/90.PUB...
Close Clearance Installations) ** Mobile Home and Alcove Installations must use double wall listed pipe, side shields and rear shield. Mobile Home Installations require Outside Combustion Air Kit # Z1526. Rev. Date: January 12, 2004 Page 9 Printed: February 8, 2005 OM-BRII/90.PUB...
BRIARWOOD II OPTIONAL COMPONENTS Your Briarwood Residential and Mobile Home Stove is listed for use with the following components: Z1514 Blower Unit, Z1526 Outside Combustion Air Kit, Z1234 Rear Heat Shield Kit, Z1539 Mobile Home Anchor and Grounding, Z5678 Gold Door Trim Kit, and S/SBRII90 Side Heat Shields (Rear shield or Fan Kit Required).
Check all local codes and regulations regarding your installation before you begin. *** DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. *** Rev. Date: January 12, 2004 Page 11 Printed: February 8, 2005 OM-BRII/90.PUB...
Also required for close clearance installation are Attach chimney connector to the side shield kit and rear shield kit. collar with screws provided Floor Protector FIGURE Rev. Date: January 12, 2004 Page 12 Printed: February 8, 2005 OM-BRII/90.PUB...
Mobile Home Installation requires certain methods and components not necessary for Residential Installation to conform to UL and/or standards and applicable building codes. Briarwood II Stoves have been tested and listed for these requirements with the use of the correct components and methods, herein described.
General GRATES OR ANDIRONS Briarwood Stoves are designed for the burning of wood directly on the firebrick. Best efficiency and burn characteristics are obtained when a half inch bed of ashes is maintained in the firebox. STARTING YOUR FIRST FIRE (Curing Your Stove Paint) Make sure you provide extra ventilation by opening a door or window as the paint will give off fumes while it is curing.
** USE CARE WHEN ROUTING THE POWER CORD, MAKE SURE IT IS NOT UNDERNEATH THE BASE OF THE STOVE. ** Fan Kit Electrical Diagram Motor Rheostat White Green Green Ground Screw With Star Washer Rev. Date: January 12, 2004 Page 15 Printed: February 8, 2005 OM-BRII/90.PUB...
Need help?
Do you have a question about the BRII/90 and is the answer not in the manual?
Questions and answers