Summary of Contents for Blaze King BRIARWOD BRII/90
Page 1
BRIARWOD BRII/90 SOLID FUEL STOVE Th is heater meets the 2015 U.S. Environmental Protection Agency’s particulate emission limits for wood heaters sold aft er May 15, 2015. Installer: Please complete the details on the back cover and leave this manual with the homeowner.
BRII/90 Page 4 INTRODUCTION • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED BY FEDERAL AND STATE LAWS. •...
MODEL: BRII/90 Tested to : UL1482-1998 / ULC S627-M93 CERTIFIED IN BOTH UNITED STATES AND CANADA PREVENT HOUSE FIRES - Install and use only in accordance with Blaze King’s installation and operation instructions. Contact local building or fire officials about restrictions and installation inspection in your area.
Page 8 SAFETY PRECAUTIONS IF THIS BLAZE KING STOVE IS NOT PROPERLY INSTALLED OR OPERATED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
Page 9
BRII/90 Page 9 SAFETY PRECAUTIONS cont. Never try to repair or replace any part of this appliance Do not place clothing or other unless instructions are given fl ammable items on or near in this manual. All other work this appliance. must be done by a trained technician.
Page 10
BRII/90 Page 10 SAFETY PRECAUTIONS cont. This appliance is designed and approved for burning cord wood only. DO NOT burn trash, garbage; artifi cial or paper logs; gift wrappings; coal; lighter fl uids; chemical cleaners; chemical starters; treated or painted wood; salt water driftwood or foil-backed paper such as gum wrappers or cigarette packages;...
CAN CATCH FIRE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48”(1219 MM) FROM THE FRONT OF THE APPLIANCE. Blaze King grants no warranty, implied or stated, for the installation or maintenance of the appliance and assumes no responsibility of any consequential damage(s).
BRII/90 Page 12 INSTALLATION INSTRUCTIONS cont. MINIMUM CLEARANCES for BRII/90 Residential Installations Single wall pipe (24 MSG Black). 15” 15” 28.75” 22” 15” 28.875” 381 mm 381 mm 731 mm 559 mm 381 mm 734 mm Listed double wall pipe - close clearances. Use side shields and rear 14”...
Blaze King therefore recommends vertical installations with a minimum length of 15’ from stove top to chimney cap. In all freestanding stove installations, use double wall stove pipe from the stove top to the ceiling support box.
BRII/90 Page 14 INSTALLATION INSTRUCTIONS cont. VENTING SYSTEMS Th e venting system consists of a chimney connector and a chimney. Th ese get extremely hot during use. Temperatures inside the chimney may exceed 2000 degrees in the event of a creosote fi re. To protect against the possibility of a house fi re, the chimney connector and chimney must be properly installed and maintained.
Page 15
BRII/90 Page 15 INSTALLATION INSTRUCTIONS cont. CONNECTION TO A METAL PREFABRICATED CHIMNEY When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed precisely. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass through and “T”...
Page 16
1” clear of the wall. ***Blaze King recommends the use of a Stainless steel liner, preferably insulated, inside a masonry chimney. Th is to maintain proper draft and overall better operation of the unit.
BRII/90 Page 17 INSTALLATION INSTRUCTIONS cont. MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS) Use double wall listed pipe, side shields, and rear shield (See next page for kits and part numbers). Mobile home installations also requires an outside air kit #Z1526. Th ey are easiest to mount before the stove is installed. See instructions packed with each kit.
INSTALLATION: See instructions included with fan kit. ELECTRICAL CONNECTION: Your Blaze King fan kit is equipped with a three-prong (grounded) plug to decrease shock hazard. THIS PLUG SHOULD BE INSERTED DIRECTLY INTO A PROPERLY-GROUNDED, THREE- HOLE RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.
Page 19
BRII/90 Page 19 INSTALLATION INSTRUCTIONS cont. DOOR INSTALLATION AND CHANGE-OUT To install the door upon stove installation or to change it out, follow these steps: DOOR IS HEAVY, PLEASE HOLD FIRMLY. INSTALLATION 1. Insert the top of door hinge rod into the top hinge hole on the fi rebox. 2.
BRII/90 Page 20 OPERATING INSTRUCTIONS YOUR FIRST FIRE! Th e following pages contain information on the major components and operation of your heater. Please take time to read about them as it will give you a better understanding of how your stove works. Th is understanding will help you to operate your stove properly thus will extend the life of your stove and allow you to get the highest effi ciencies from your heater.
Th e more seasoned (dry) the wood, the higher the effi ciency (less energy wasted on eliminating moisture during combustion). Operating your Blaze King at lower settings will result in higher effi ciencies as the fuel will undergo a more complete combustion. For maximum effi ciency, the appliance should be installed in a location that provides adequate intake/combustion air as well as a location that will allow for the straightest run of optimal chimney length to establish necessary draft .
3. Open the loading door. 4. Place 10 balls of non-glossy paper towards the front of the bottom of the fi rebox, or use a Blaze King fi re starter puck, then stack 20 pieces of kindling on top of the paper in a crisscross fashion (leaving air gaps in between sticks).
BRII/90 Page 23 OPERATING INSTRUCTIONS cont. FAN OPERATION If you have the fan system installed, the fan should be off for 20 - 30 minutes until the stove reaches normal operating temperatures. Th e fan speed adjustment should match the draft control setting, i.e. if your stove is set at medium then your fan should also be set at medium, low—low, high—high etc..
BRII/90 Page 24 MAINTENANCE RUN-AWAY OR CHIMNEY FIRE A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRE DAMAGE IS NOT COVERED BY THE LIMITED WARRANTY. CAUSES: 1.
BRII/90 Page 25 MAINTENANCE cont. CHIMNEY MAINTENANCE Th e most effi cient method to sweep the chimney is using a hard brush. Brush downwards so soot and creosote residues will come off the inner surface and fall to the bottom of the chimney where they can be removed easily. Th e chimney must be checked regularly and if creosote has accumulated, it must be removed without delay.
BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK 1. If the door gasket is to be replaced, be sure you have Blaze King 7/8” fi ber glass gasket ready to re-install, as well as high temperature adhesive. See your Blaze King dealer.
DOOR GLASS GASKET REPLACEMENT BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK 1. You will require Blaze King glass gasket and Blaze King door gasket. Please see your Blaze King dealer. 2. Remove the old glass gasket. 3. Starting at the top right corner, carefully wrap the gasket around the edges, pressing fi rmly onto the sides of the glass with the gasket centered on the edge.
BRII/90 Page 28 MAINTENANCE cont. LOADING DOOR TENSION ADJUSTMENT To tighten the door seal: 1. Open the loading door. 2. Rotate the handle counter-clockwise one rotation (Fig. A). 3. Repeat paper test. (see “LOADING DOOR GASKET INSPECTION” on page 37) 4.
BRII/90 Page 29 MAINTENANCE cont. BAFFLE REPLACEMENT Th e baffl e is the part of the stove that receives the most heat. For this reason, as well as for chimney cleaning ease, it was designed for easy removal. Remove the two allen head cap screws and washers from each side of baffl e support plates (Fig. A) to allow the baffl e to slide forward and out (Fig.
TROUBLESHOOTING Your Blaze King is designed to allow a wide selection of heat output levels. If you begin to lose control of the amount of heat the stove is emitting, determine the cause early so that major problems may be avoided.
Page 31
Measure draft with Manometer. See “DRAFTS”. Consult your Blaze King dealer or a chimney sweep. Chimney too cold or poorly insulated. Upgrade chimney system. Consult your Blaze King dealer or a chimney sweep. PROBLEM: Spots of creosote accumulation in chimney or chimney connector.
Page 32
BRII/90 Page 32 REPLACEMENT PARTS cont. ITEM PART DESCRIPTION QTY. NUMBER 0186A-6ft Gasket 7/8” hard rope for Briarwood 0254AS-6ft 1/8” window gasket 0730 Robax Glass 10 5/8” x 21 5/8” ZBR518 Door without glass ZBR518P-C Door with glass, no handle OM-BRII90 E V1.03 wo739 July 14, 2015...
Page 33
BRII/90 Page 33 REPLACEMENT PARTS cont. Briarwood Brick Layout OM-BRII90 E V1.03 wo739 July 14, 2015...
WARRANTY BLAZE KING WOOD LIMITED WARRANTY Blaze King and Valley Comfort’s respective brands extend the following warranty for wood fi red appliances purchased from an authorized Blaze King / Valley Comfort dealer and installed in the United States of America or Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.
Page 35
If you are not satisfi ed with the service provided by the Blaze King dealer, write to Blaze King at the address listed on the last page of the Owner’s Manual. Include a copy of the original purchase invoice and a description of the problem.
Page 36
Blaze King The use of such products may nullify the Limited Warranty on this stove. If unsure as to the extent of this Limited Warranty, contact your authorized Blaze King dealer before installation.
Page 37
For parts of the Blaze King woodstove or fi replace insert warranted beyond the fi rst year, the fi ve year limited warranty will have the same obligations as described in this document, provided, however that the purchaser shall pay the following percentage of the then current retail cost of the repair or the replacement, according to the year after purchase in the which the defect is brought to the attention of Blaze King.*** During the 2nd year----purchaser pays...
Page 38
BRII/90 Page 38 NOTES OM-BRII90 E V1.03 wo739 July 14, 2015...
Page 39
BRII/90 Page 39 NOTES OM-BRII90 E V1.03 wo739 July 14, 2015...
BRII/90 Page 40 INSTALLER NOTES Installer: Please complete the following information Dealer Name & Address:________________________________________________________ ____________________________________________________________________________ Installer (print): _______________________________________________________________ Installer (sign): _______________________________________________________________ Phone #: ____________________________________________________________________ Date Installed:________________________________________________________________ Serial No.: ___________________________________________________________________ OM-BRII90 E V1.03 wo739 July 14, 2015...
Need help?
Do you have a question about the BRIARWOD BRII/90 and is the answer not in the manual?
Questions and answers