Page 3
Installation must conform with local codes or in the absence of local codes with: In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.” In Canada, installation must comply with Standards CSA-B149.1 or Natural Gas and Propane Code CSA C22.1, latest edition, Canadian Electric Code, Part I.
Introduction Serial Plate Location When calling or writing for information about your product, be sure to mention model and serial numbers. Model and serial numbers are found on serial plate on rear of machine, and/or inside door hinge. Refer to Figure 1.
Safety Information Precautionary statements (“DANGER,” NOTE: The word “NOTE” is used to communicate “WARNING,” and “CAUTION”), followed by installation, operation, maintenance or servicing specific instructions, are found in this manual and on information that is important but not hazard machine decals. These precautions are intended for the related.
Safety Information Save These Instructions Important Safety Instructions 14. The interior of the tumbler and the exhaust duct should be cleaned periodically by qualified service personnel. WARNING 15. If not installed, operated and maintained in accordance with the manufacturer’s instructions To reduce the risk of fire, electric shock, or if there is damage to or mishandling of this serious injury or death to persons when...
Page 11
Safety Information 23. Remove laundry immediately after tumbler 29. DO NOT bypass any safety devices. stops. 30. Solvent vapors from dry-cleaning machines 24. Always read and follow manufacturer’s create acids when drawn through the heater of the instructions on packages of laundry and cleaning drying unit.
Operating Instructions WARNING To reduce the risk of fire: • DO NOT DRY articles containing foam rubber or similarly textured rubberlike materials. • DO NOT DRY plastics, anything containing wax or chemicals such as mops and cleaning cloths, or anything dry-cleaned at home with a dry-cleaning solvent. •...
Operating Instructions COOL HEAT DOWN HIGH PUSH START TMB47N Figure 3 Manual Timer IMPORTANT: If the door is opened during the cycle, the heating system will shut off and the 1. Set the HEAT (Drying) timer for the number of motor will stop.
Operating Instructions STATUS PROGRAM ON / SELECT HIGH START AUTO TIME DRYING AUTO SPECIAL SPECIAL MEDIUM STOP/RESET COOL DOWN CYCLE TIME AUTO COOL MED LOW TEMP TEMP DOOR OPEN DOWN DISPLAY F/ C SIGNAL CUSTOM MORE LESS SAVE NO HEAT CONDITION CUSTOM PROG...
Operating Instructions SELECT INSERT PUSH TEMPERATURE TEMP COIN START HIGH INSERT QUARTER TURN KNOB PUSH START TMB807N Figure 6 Electromechanical Coin Control IMPORTANT: If the loading door or lint panel door is opened during the cycle, the heating system 1. Set the TEMPERATURE selector at HIGH or will shut off and the motor will stop.
Operating Instructions SELECT INSERT PUSH TEMP COIN START HIGH START TEMP TEMP TEMP HEAT T361I T361I Figure 7 Electronic Coin Control IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the 1. Select HIGH TEMP, MED TEMP, LOW TEMP tumbler, CLOSE door and press START pad.
Operating Instructions C851I C851I Figure 8 NetMaster Coin Control IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the 1. Select HIGH TEMP, MED TEMP, LOW TEMP tumbler, CLOSE door and press START pad. or NO HEAT by pressing the appropriate temperature pad.
Operating Instructions C852I C852I Figure 9 NetMaster Card Control IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the 1. Select HIGH TEMP, MED TEMP, LOW TEMP tumbler, CLOSE door and press START pad. or NO HEAT by pressing the appropriate temperature pad.
Operating Instructions SELECT INSERT INSERT PUSH TEMP COINS CARD START DRYING COOL DOWN START DELICATES TMB1964N Figure 10 MDC Coin Control IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the 1. Select HIGH TEMP, MED TEMP, LOW TEMP tumbler, CLOSE door and press START pad.
Operating Instructions SELECT PUSH TEMP START DRYING COOL DOWN INSERT CARD HERE START DELICATES TMB1965N Figure 11 MDC Card Control IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the 1. Select HIGH TEMP, MED TEMP, LOW TEMP tumbler, CLOSE door and press START pad.
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. •...
Page 24
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. •...
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. •...
Page 26
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. •...
Before You Call for Service Won’t Won’t Clothes Possible Reason – Corrective Actions Start Heat Not Dry Insert correct coin(s) or valid card if applicable. • Close the loading door tightly. • Close lint panel tightly. • Press the PUSH TO START button. •...
Need help?
Do you have a question about the DA11-15 and is the answer not in the manual?
Questions and answers