Download Print this page

Curtis EXPR Service Manual

Expressions multi-flavor

Advertisement

Quick Links

Model Included:
■ EXPR
WARNING HOT
LIQUID, Scalding
may occur. Avoid
splashing.
CAUTION: Use this
setup procedure
before attempting
to use this appliance. Failure
to follow the instructions can
result in injury or the voiding
of the warranty.
CAUTION: DO NOT
connect this unit to
hot water. Inlet valve
not rated for hot water.
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO.
Montebello, CA 90640
For the latest information go to
www.wilburcurtis.com
Tel: 800/421-6150
W
Service Manual – Expressions Multi-flavor
Important Safeguards/Symbols
This equipment is designed for commercial use. Any servicing other than cleaning and routine
maintenance should be performed by an authorized Wilbur Curtis Company Service Technician.
• DO NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, DO NOT open service panels. There are no
user serviceable parts inside.
• Keep hands and other items away from hot areas of the unit during operation.
• Never clean with scouring powders or harsh chemicals.
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
This Curtis Generation 3 Unit is Factory Pre-Set and Ready to Go Right from the Box.
Following are the Factory Settings for your Expressions Multi-flavor Beverage System:
• Tank Temperature = 190°F
• Dispensing Mode Set for Manual Dispense
Generally there will never be a reason to change your G3 programming. However, should you need
to make slight adjustments to meet your dispensing needs, programming instructions are provided
later in this manual.
System Requirements:
• Water Source 20 – 90 PSI (Minimum Flow Rate of 1 GPM)
• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for
your model.
SETUP STEPS
1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume flow to the machine
should be consistent. Use tubing sized sufficiently to provide a minimum flow rate of one gallon per minute.
NOTE: A water filtration system must be used to help maintain trouble-free operation. In areas with ex-
tremely hard water, we highly recommend the use of a Curtis approved water filter. For our full line of filters,
please log on to www.wilburcurtis.com. A water filtration system will greatly prolong the life of the unit and
enhance the quality and taste of the product.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so
that the unit can be moved for cleaning.
2. This unit must be installed with adequate backflow protection to comply with applicable federal,
state and local codes.
3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized,
installed and maintained in accordance with federal, state, and local codes.
3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4. Once power has been supplied to the unit, flip the toggle switch to the 'ON' position (located on the rear of
the unit), the water tank will begin to fill. When the water level in the tank reaches the probe, the heating
element(s) will turn on.
5. Water in the heating tank will require approximately one hour before reaching operating temperature (factory
setting of 190°F). Where applicable, turn on the Universal Control Module (UCM). When the unit reaches
operating temperature, it will display "READY TO BREW".
C
C
ilbur
urtis
, i
.
ompany
nC
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the EXPR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Curtis EXPR

  • Page 1 WARNINGS – To help avoid personal injury Important Notes/Cautions – from the factory Sanitation Requirements This Curtis Generation 3 Unit is Factory Pre-Set and Ready to Go Right from the Box. Model Included: Following are the Factory Settings for your Expressions Multi-flavor Beverage System: ■...
  • Page 2: Operation Instructions

    4. Refill all canisters with product, then reposition them on the machine, aligning the gear socket with the gear on the motor shaft. 5. Rotate the powder delivery elbows downward and close the front door. Cleaning the Curtis Multi-flavor Beverage Dispenser CAUTION - Do not use cleansers, liquid bleach, powders or any other substance containing chlorine.
  • Page 3 11. The unit is ready for use. Steps to Programming Your Curtis Generation 3 Multi-Flavor Dispenser is Factory Pre-Set for Optimum Performance. Entering the Programing Menus Press and hold STOP/WASH for about ten [10] seconds until display reads Program Menus (See Illustration). Release button.
  • Page 4 Program Menus Manual Dispense (Factory Default) Press  or ► to go to Manual Dispense Select. Press  to go to Manual Dispense Select Station. Choose the station and press, the display will read Saving Complete! To select another station for manual dispense, press  to go to Manual Dispense Select Station or press ►...
  • Page 5: Rough-In Drawing

    ULTRA-SLIM MODEL P/N CA-1113-06R P/N CA-1142-06 EXPR FOUR Whipper Plate – Shaft Seals Shaft seals should be replaced with the groved side facing outward. Place a dab of food grade lubricant in the rear hole of the seal, as shown below.
  • Page 6 Part № Description Item № Part № Description WC-58222 COVER, TOP WC-39608 LABEL, UCM PANEL WC-68191 PANEL, LEFT SIDE EXPR CA-1142-06 CANISTER, ASSY ULTRA SLIM WC-68175 BRACE, LEFT SIDE CA-1113-06R CANISTER ASSY, 10LB RIGHT PCGTs WC-58232 DOOR, COMPLETE CA-1127 *...
  • Page 7 Illustrated Parts – Chassis Item № Part № Description Item № Part № Description CA-1005-03 * STEAM TRAP CA-1163 COVER, ALCOVE CA-1095 CONNECTOR, ORIFICE WATER PCGT WC-68160 SCREEN, DRIP TRAY CA-1009-03 * BOWL, MIXING CA-1160 DRIP TRAY WC-37118 * KIT, WHIPPER PLATE (W/SEAL) 3/PKG CA-1142 LID, CANISTER, ULTRA SLIM CA-1008-07K *...
  • Page 8 Description WC-58229 EXTENSION, GEAR MOTOR SHAFT WC-8591 * CAPACITOR, X2 ALL ADS MODELS WC- 796 * UNIVERSAL POWER MODULE EXPR WC-3518 LEG, GUIDE 3/8”-16 STUD SCREW WC-5231 * COMPOUND, SILICONE 5 OZ TUBE WC-5310 * TUBE, 5/16” ID X 1/8”w SILICONE CA-1030-23 HOSE, EXTRACTOR FAN 23”...
  • Page 10: Product Warranty Information

    Product Warranty Information The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use. The following limited warranties and conditions apply: 3 Years, Parts and Labor, from Original Date of Purchase on digital control boards.

This manual is also suitable for:

Expressions multi-flavor expr