SPARK   P LUG   M AINTENANCE:  
1. Remove   S park   P lug   C ap   ( refer   t o   " Spark   P lug   C ap   R emoval"   f igure   b elow.)  
2. Remove   S park   P lug   w ith   s ocket   a nd   h andle   s upplied   w ith   y our   u nit   ( refer   t o  
"Spark   P lug   R emoval"   f igure   b elow.)  
3. Clean   a ny   c arbon   b uild-­‐up   a round   t he   S park   P lug.  
4. Check   t he   S park   P lug   G ap   a nd   a djust   i f   n ecessary.       0 .30-­‐inch   g ap.  
5. Lubricate   t he   t hreads   o f   t he   S park   P lug   w ith   a nti-­‐seize   c ompound   o r   e ngine   o il.    
6. Re-­‐install   t he   S park   P lug   a nd   S park   P lug   C ap.  
 
              S park   P lug   C ap   R emoval  
 
 
FUEL   S YSTEM   M AINTENANCE:  
NOTE:   P eriodically   y ou   c an   g et   s ediment   o r   t rash   i n   y our   C arburetor   B owl.     U se   t he  
following   p rocedures   t o   c lean:  
1. Turn   t he   f uel   c ock   ( valve)   t o   t he   " OFF"   P osition.  
2. Remove   t he   c arburetor   b owl   b y   r emoving   t he   m ounting   b olt   l ocated   a t   t he  
bottom   o f   t he   b owl.  
3. Dump   o ut   t he   o ld   f uel   a nd   s ediment   i nto   a n   a pproved   c ontainer   a nd   c lean  
carburetor   b owl   t horoughly.  
4. Fit   a   n ew   r ubber   w asher   i nto   p lace   a nd   r e-­‐attach   f uel   b owl   t o   t he   c arburetor.  
NOTE:   R emoval   o f   t he   d rain   s crew   a t   t he   b ottom   o f   t he   b owl   c an   d rain   t he   f uel   t o  
remove   s maller   d ebris   t hat   h as   c ollected   i n   t he   b owl.  
5. After   b owl   i s   s ecurely   b ack   i n   p lace,   t urn   t he   f uel   c ock   ( valve)   t o   t he   " ON"  
position   f or   u se.  
6. Units   e quipped   w ith   a   p re-­‐filter   f or   f uel   w ill   h ave   a   f ilter   h oused   j ust   b elow   t he  
fuel   c ock.     R emove   t he   f uel   f ilter   e lement   ( refer   t o   " Fuel   F ilter   E lement   R emoval"    
 
Maintenance   ( continued)  
 
 
 
 
 
 
 
 
LIFAN   P ower   U SA  
2205   I ndustrial   P ark   R oad  
Van   B uren,   A R   7 2956  
866-­‐471-­‐7464  
www.lifanpowerusa.com  
 