Physical and electrical specifications

Dimensions:
Height: 43 mm (1.7 in)
Width: 440 mm (17.3 in)
Depth: 711 mm (28.0 in)
Weight:
Minimum configuration 12.7 kg (28 lb)
Maximum configuration 15.9 kg (35.1 lb)
Supported environment:
Air temperature:
Server on: 10 to 35° C (50.0 to 95.0° F); altitude: 0 to 914.4 m (3,000 ft).
Decrease system temperature by 0.75° C for every 1,000-foot increase in altitude.
Server off: 5 to 45° C (41.0 to 113° F);
Shipment: -40 to +60° C (-40 to 140° F);
Humidity:
Server on: 20 to 80% , maximum dew point 21° C, maximum rate of change 5° C/hr
Server off: 8 to 80%, maximum dew point 27° C
Electrical:
Models with 675 W power supply
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 7.8 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.8 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
Maximum configuration: 0.78 kVA
Models with 460 W power supply
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 5.3 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 2.6 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
Maximum configuration: 0.53 kVA
BTU heat output:
Minimum configuration: 307 Btu/hr (90 watts)
Maximum configuration: 2660 Btu/hr (780 watts)
Acoustical noise level emission level:
6.1 bels (idling)
6.1 bels (operating)