CIX40 Installation
Installing the CIX40 Cabinet
6. Connect a #10 ground AWG wire from the HPFB-6 "FG" screw to the CIX40 screw labeled
"TB1"
Note The CIX40 should be plugged into AC power and the DC power switch should be turned On
when installing the HPFU-6. The HPFU-6 will not start to operate if AC power is not
available during the initial installation.
7. The 24VDC LED on the HPFB-6 should light. If it does not light, press the battery Off switch
with a pencil point or other small-tipped object.
8. Dress and tie-wrap the HPFB-6 cables.
9. To mount a second HPFB-6, repeat Steps 1~4, then plug the second HPFB-6 connector in the
first HPFB-6 and connect an FG wire between each HPFB-6 FG screw.
10. To test the HPFB-6, remove the CIX40 AC plug from the AC outlet. The CIX40 AC LED will go
out, but the CIX40 DC LED remains on. Also the system remains in normal working order and
the HPFB-6 24V LED remains on.
11. If it is desired to turn off the HPFB-6 (after loss of AC power), use a pencil or other sharp
object to press the Battery Off switch.
CAUTION! Once the HPFB-6 is turned Off or unplugged (during AC power loss) it will
Note The CIX40 Cabinet does not provide a battery charger, the HPFB-6 contains built-in
batteries and a battery charger; therefore, do not connect any other type of batteries to the
CIX40.
Figure 1-22 HPFB-6 Connection
1-30
(Figure
1-22).
not operate again until AC power is restored to the CIX40 Cabinet.
BATT
TB1
Battery Cable
ON / Standby
Switch
Strata CIX40 Installation & Maintenance