Self-Tests; Running Parameter Tests - Philips Vari-Lite VL3015 Spot Luminaire User Manual

Flood light
Table of Contents

Advertisement

VARI
LITE VL3015 / VL3515 S

Self-Tests

Running Parameter Tests

The luminaire is capable of running self-tests by using the Test menu functions.
When running tests on multiple luminaires, a DMX termination connector is required at the last
luminaire in the link. Refer to
regarding the construction of this connector.
Note: After 10 seconds of inactivity, the menu display will change to the default state showing the
address.
To connect luminaires for simultaneous testing:
Step 1. At last luminaire, install a DMX termination connector into DATA THRU XLR connector.
Step 2. At master luminaire Menu Display, press [Menu].
Master Luminaire
To run tests:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Test appears. Press [Enter].
Step 3. Use [Up] / [Down] arrows to select a parameter to test. Refer to
System Function Chart" on page 67
for a complete list of test parameters which can be chosen.
Step 4. Press [Enter] to run test.
Step 5. Press [Menu] to stop test at any time.
76
L
POT
UMINAIRE
"Connecting Data and Power" on page 17
~
AC IN
DATA IN
DATA THRU
MENU
ENTER
Data Thru
Figure 4-2: Testing Setup
U
'
M
SER
S
ANUAL
Luminaire 1
~
AC IN
DATA IN
DATA THRU
MENU
ENTER
Data Thru
or
"VL3515 Menu System Function Chart" on page 71
2 7 Au gu st 2 013
for more information
Luminaire 2
~
AC IN
DATA IN
DATA THRU
MENU
ENTER
DMX Termination Connector
"VL3015 Spot Menu
02 .9 679 .00 02 A