SL BAR 660 RGBW LED Luminaires Installation & User’s Manual IMPORTANT INFORMATION Warnings and Notices When using electrical equipment, basic safety precautions should always be followed including the following: a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b. Do not use outdoors.
About this Manual ..................................3 Included Items..................................... 3 Accessories ....................................3 SL BAR 660 RGBW LED Luminaire Power Input Cables (North American Models Only)..........3 SL BAR 660 RGBW LED Luminaire Accessories ......................3 SL BAR 660 RGBW LED LUMINAIRE OVERVIEW SL BAR 660 RGBW LED Luminaire Components........................
Page 5
Installation & User’s Manual HSIC Mode ....................................30 HSIC Group Modes .................................. 31 SL BAR 660 RGBW LED Luminaire DMX Timing Channel Detail ..................32 SL BAR 660 RGBW LED Luminaire RDM Parameter IDs ....................38 CLEANING AND CARE Special Cleaning and Care Instructions ............................ 42 Front Lens Cleaning..................................
SL BAR 660 RGBW LED Luminaire Power Input Cables (North American Models Only) Part Number Description SL BAR 660 RGBW LED Luminaire AC Power Input Cable (39 inches / 1 meter), Powercon with Bare PC1BE End* (*Note, user supplies and installs own AC input connector)
DMX512 / DMX512 / LCD Display / Menu System RDM Output RDM Input Figure 2: SL BAR 660 RGBW LED Luminaire Components Note: *Mounts can be removed and reversed. See "Mounting Luminaire" on page 10 for more information Sh wline...
(with rotation of menu) Figure 3: LCD Display & Menu System Note: For Menu operation and programming details, refer to "LCD Display and Menu System" on page Sh wline SL BAR 660 RGBW LED LUMINAIRE OVERVIEW...
INSTALLATION AND SET UP 1. Power Requirements The SL BAR 660 RGBW LED Luminaire operates on AC input voltages from 100 to 240 VAC. WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use.
Table 2 on page 8 describes how to connect power to your SL BAR 660 RGBW LED Luminaire. Field wiring of the SL BAR 660 RGBW LED Luminaire is straight forward. A total of 3 wires/conductors is supplied from the unit. The...
SL BAR 660 RGBW LED Luminaire. Another cable runs from the other DMX connector on the first unit to a DMX connector on the next SL BAR 660 RGBW LED Luminaire (or DMX512 device to be controlled).
Simply attach hook, clamp, etc. to the SL BAR 660 RGBW LED Luminaire mount assembly in the M13 hole. Note: Mounting hooks, clamps, etc. are sold separately or by others. For available mounting accessories refer to "Accessories"...
Installation & User’s Manual OPERATION AND PROGRAMMING 1. LCD Display and Menu System The SL BAR 660 RGBW LED Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings: • Presets (Standard and User Defined) •...
Figure 8: LCD Display and Menu System 3. SL BAR 660 RGBW LED Luminaire Main Menu Options Presets Presets are stored values of the luminaire's LED settings that can be recalled via the menu system or DMX. You can customize up to 31 presets via the menu system.
Delete the currently selected step in the Edit Step field. Press the Check Mark button to Delete Step delete the current step. Rainbow Press the Check Mark button to display the Rainbow Chase editor. Sh wline SL BAR 660 RGBW LED Luminaire Main Menu Options...
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual To edit and save a Step: Step 1. Select Edit Step or New Step from the Edit User Chase menu. Step 2. The top left field indicates the preset or color filter to be used for the step. When set to OFF no preset or color filter is to be used.
Select the security level to default to when the fixture is powered ON. Power-up Level • Disable PIN will disable all security functions. • Locked will lock all functions. Sh wline SL BAR 660 RGBW LED Luminaire Main Menu Options...
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Settings/General Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different general fixture settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in Table 9.
Note: When the fixture is powered off, the Lock Fixture function will be disabled. To assign fixture power-up security refer to (see "Settings/Security" on page 15 for more information). Sh wline SL BAR 660 RGBW LED Luminaire Main Menu Options...
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Password (PassPIN) The Password menu item will display an Enter PassPIN dialog box. Use the Up Down Left Right buttons to enter a PIN code matching the codes assigned in the Settings/Security menu to toggle the current security level.
PL_Curve * DMX Value DMX Value *PL Curve follows the dimming curve of Vari-Lite Selecon PL series LED luminaries. S_Curve Square Curve DMX Value DMX Value Figure 9: SL BAR 660 RGBW LED Luminaire Dimmer Curves Sh wline Harmonize Color Calibration...
6. Master / Slave Operational Mode The Master / Slave Operational Mode allows one SL BAR 660 RGBW LED Luminaire to act as the "Master" unit and all other connected units are controlled by this unit. When a unit is set to "Slave" mode, it will only listen to and follow any commands sent from a "Master"...
1 function and other functions follow in sequence. 1. 16-Bit Mode Table 15 provides DMX channel mapping of all DMX512 control values when the SL BAR 660 RGBW LED Luminaire is in 16-bit DMX512 mode (as set by the luminaire’s menu system).
Page 24
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 15: SL BAR 660 RGBW LED Luminaire DMX Channel Mapping (16-Bit Mode) CONTINUED FROM PREVIOUS PAGE CF_11_Moroccan Pink DMX 91 - 92 CF_12_Pink DMX 93 - 94 CF_13_Flesh Pink DMX 95 - 96...
Page 25
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 15: SL BAR 660 RGBW LED Luminaire DMX Channel Mapping (16-Bit Mode) Allows for timing control of intensity. Channel Intensity Timing 0 - 255 0 - 100% should default to 255 for smoothest actions using console and/or manual fades.
Installation & User’s Manual 2. 16-Bit Group Modes Table 16 provides DMX channel mapping of all DMX512 control values when the SL BAR 660 RGBW LED Luminaire is operated in various 16-bit DMX512 Group Control Modes. Table 16: SL BAR 660 RGBW LED Luminaire DMX Channel Mapping (16-Bit Group Modes)
Installation & User’s Manual 3. 8-Bit Mode Table 17 provides DMX channel mapping of all DMX512 control values when the SL BAR 660 RGBW LED Luminaire is in 8-bit DMX512 mode (as set by the luminaire’s menu system). Table 17: SL BAR 660 RGBW LED Luminaire DMX Channel Mapping (8-Bit Mode)
Page 28
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 17: SL BAR 660 RGBW LED Luminaire DMX Channel Mapping (8-Bit Mode) CONTINUED FROM PREVIOUS PAGE CF_29_Marine Blue DMX 127 - 128 CF_30_Soft Green DMX 129 - 130 CF_31_Moss Green DMX 131 - 132...
Page 29
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 17: SL BAR 660 RGBW LED Luminaire DMX Channel Mapping (8-Bit Mode) Control Channel functions of the SL Series products. Set control channel value from 0 then turn to desired action. Hold value for at least 5 seconds, then turn to 0.
Installation & User’s Manual 4. 8-Bit Group Modes Table 18 provides DMX channel mapping of all DMX512 control values when the SL BAR 660 RGBW LED Luminaire is operated in various 8-bit DMX512 Group Control Modes. Table 18: SL BAR 660 RGBW LED Luminaire DMX Channel Mapping (8-Bit Group Modes)
Installation & User’s Manual 5. Simple RGBW 8-Bit Mode Table 19 provides DMX channel mapping of all DMX512 control values when the SL BAR 660 RGBW LED Luminaire is in Simple RGBW 8-bit DMX512 mode (as set by the luminaire’s menu system).
Installation & User’s Manual 6. Simple RGBW 8-Bit Group Modes Table 16 provides DMX channel mapping of all DMX512 control values when the SL BAR 660 RGBW LED Luminaire is operated in various Simple RGBW 8-bit DMX512 Group Control Modes.
Installation & User’s Manual 7. HSIC Mode Table 21 provides DMX channel mapping of all DMX512 control values when the SL BAR 660 RGBW LED Luminaire is in HSIC (Hue, Saturation, Intensity, and Color Correction) DMX512 mode (as set by the luminaire’s menu system).
Installation & User’s Manual 8. HSIC Group Modes Table 22 provides DMX channel mapping of all DMX512 control values when the SL BAR 660 RGBW LED Luminaire is operated in various HSIC DMX512 Group Control Modes. Table 22: SL BAR 660 RGBW LED Luminaire DMX Channel Mapping (HSIC Group Modes)
9. SL BAR 660 RGBW LED Luminaire DMX Timing Channel Detail Timing channel control improves the timed moves of certain groups of parameters. The SL BAR 660 RGBW LED Luminaire provides timing channels in 16-bit mode (one for intensity time and one for color time) and one timing channel in 8-bit (color and intensity timing combined).
Page 36
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 23: SL BAR 660 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) 10.2 10.4 10.6 10.8 11.2 11.4 11.6 11.8 12.2 12.4 12.6 12.8 13.2 13.4...
Page 37
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 23: SL BAR 660 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) 16.6 16.8 17.2 17.4 17.6 17.8 18.2 18.4 18.6 18.8 19.2 19.4 19.6 19.8...
Page 38
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 23: SL BAR 660 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) Sh wline DMX CONTROL...
Page 39
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 23: SL BAR 660 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) Sh wline SL BAR 660 RGBW LED Luminaire DMX Timing Channel Detail...
Page 40
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 23: SL BAR 660 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) 5 Minutes 15 Minutes 30 Minutes 60 Minutes 250* 60mS 251* 80mS 252*...
• Table 27, “SL BAR 660 RGBW LED Luminaire RDM Manufacturer Status IDs,” on page 41 • Table 28, “SL BAR 660 RGBW LED Luminaire RDM Manufacturer Specific PIDs for Root Device,” on page 42 • Table 29, “SL BAR 660 RGBW LED Luminaire RDM Manufacturer Specific PIDs for Sub Device,” on page 42...
Page 42
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 26: SL BAR 660 RGBW LED Luminaire RDM Parameters IDs RDM Parameter IDs Value Comment Implemented Allowed Allowed Category - Network Management ■ DISC_UNIQUE_BRANCH 0x0001 ■ DISC_MUTE 0x0002 ■...
Page 43
PRESET_PLAYBACK 0x1031 Table 27: SL BAR 660 RGBW LED Luminaire RDM Manufacturer Status IDs Manufacturer Specific messages are in the range of 0x8000 - 0xFFDF. Each Manufacturer-specific Status ID shall have a unique meaning, which shall be consistent across all products having a given Manufacturer ID. See Table B-2, ANSI E1.20- 2010.
Page 44
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Table 28: SL BAR 660 RGBW LED Luminaire RDM Manufacturer Specific PIDs for Root Device Type Length Unit Prefix Default Description Allowed Allowed Parameter IDs Category - Manufacturer Defined PIDs - Range is 0x8000-0xffdf (See ANSI E1.20-2010 Standard, Table A-3) ■...
SL BAR 660 RGBW LED Luminaire. These types of cleaners or solvents can permanently damage the optics or housings of the fixture. If you have any questions regarding the use or care of your SL BAR 660 RGBW LED Luminaire, please contact Showline technical support or your local Authorized Dealer.
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual TECHNICAL SPECIFICATIONS 1. SL BAR 660 RGBW LED Luminaire Operational Specifications Source: RGBW LED Array (x288 - 72 Red / 72 Green / 72 Blue / 72 White - all 600 mA)
Page 47
SL BAR 660 RGBW LED Luminaires Installation & User’s Manual Notes Sh wline SL BAR 660 RGBW LED Luminaire Dimensions...
Page 48
Shewline Dallas 10911 Petal Street Dallas, TX 75238 Tel: +1 214-647-7880 Fax: +1 214-647-8031 Hong Kong Unit C, 14/F, Roxy Industrial Centre No. 41-49 Kwai Cheong Road Kwai Chung, N.T., Hong Kong Tel: +852 2796 9786 Fax: +852 2798 6545 Auckland 19-21 Kawana Street Northcote, Auckland 0627...