Addressing
Program Starting Address
The address setting for DMX console controlled systems is entered using the Menu Display (refer to
"Menu Operation" on page
Note: Refer to your console operating instructions for specific information regarding its addressing
requirements.
Program a DMX starting address:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Address appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows to enter starting address.
Step 4. Press [Enter] to set.
Program Starting Address Without Calibrating
Luminaire
It is possible to bypass the calibration sequence and go directly to the Menu Display programming in
order to pre-program an address setting.
Program starting address without calibrating luminaire:
•
While powering up luminaire, press and hold [Menu]. Program address as in
Address
•
Press and hold [Menu] until display changes from "Starting" to the DMX address.
Note: The luminaire will require a reset to restore control.
02.96 79.000 2 A
64). The luminaire retains the DMX address even if power is removed.
above.
2 7 Au gu st 2 013
I
: A
NSTALLATION
DDRESSING
Program Starting
2