Bulova Series 218 Service Manual page 32

Electric watches
Table of Contents

Advertisement

The
practice of cleaning
a
con-
vnnlional
watch, as a
routine pari
of nearly
every
repair,
results
from
the
watchmaker's knowl-
Sdgt
(Ji.it
optimum
performance
and
reliability
can
be
expected
only
when
lubrication
Is
fresh.
The
performance
of
ACCUTRON
is
relatively
unaffected
by
the
con-
dition
of the
lubrication.
Cleaning
will
not usually
be required
to
re-
store
an
ACCUTRON
timepiece
to
proper operating condition
When
cleaning
is
necessary, the
infor-
mation
an
tbi*
p»ko
is
applicable-
Cleaning
Separate
all
cap jewels
in
jeweling devices with spring-held
cap
jewels
from
pillar
plate
and
tram
bridge.
After
cleaning, replace
cap
jewel assemblies.
Ultrasonic
quipim-nt
in
necessary
for
cleaning the
ACCUTRON
movement.
The
ACCUTRON
movi-iiieni
should be
treated
exactly as
any
fine
watch movement,
with
one
exception.
The
electronic
circuit,
the tuning
fork
and
the
pawl
bridge
should
not
be
cleaned
in
ultrasonic
equipment, because of
the
possibility of
damage
to
delicate
parts.
The
tuning
fork, colls,
and
pawl
bridge
can be
cleaned
satisfactorily
by merely
dip-
ping
into
a "benzine cup"
and
thru placing
00
>
tissue to dry.
Care
should
be taken
to prev.-nl
DUHil
chips,
which
may
be
present
in
the cleaning
cup
or
on
the
bench, from
being
attracted
In
the
permanent magnets on
the
linn
of
the
tuning
fork.
Inspect the fork
carefully
after
cleaning,
anil
if
this
has occurred.
any
particles
ih.ii
linging
(•
thi
mtgDtto can be removed with masking
tape.
NO
PARTICLES
SHOULD
IIK
LEFT
CUNCINC
TO
FORK MAGNETS.
The
center whei'l
.muenibly
[cannon
pinion with center whcell
should
not
be token
apart,
but
cleaned
an
n
unit.
Aftur
cleanimt.
tin-
whirl should
not
be
rotated
until
properly
lubricated.
(See reassembly
instruction
Page
33.
J
Tin-
index
wind
required special
handling
care
in
cleaning
to
prevent
damage
io
the
!,,!li
I
of
this
purpose,
it
iu
necessary
tu
use
a
suitable tool
to
grasp
the
index
wheel
pivots
when
imtmTrung
the
index
wheel
in
the ultrasonic
cleaner.
NEVER
HANDLE TUB
INDEX
WHEEL
HY
THE
RIM-
GRASP THE
PINION
ONLY
A
mi
table
holding
loot for
cleaning the index
wheel
can
easily
be
fabricated
by
modifying
an ordinnry
pair
of
watchmaker's tweeter*
made
of
brass or Othtl
"<"'
magnetic
material. || follows:
L.
Spot
drill
the
insider,
oi the
tweezer
tips
as
shown
in
the
upper
section of
Fig,
32.
2.
Bend
a
piece
ol
stiff
win- around
the
tweezers
and form
the
wire so
that
it
can
be used as
a
clamp.
One
end
of the
wire should
be
placed
between
the
tweezer
tongs.
1
Check
thai
wire clamp
locks
tweezer
tips
progressively closer together as
clamp
is
pushed towards
the
tips.
Note: Authuri/rd Material
Distributors
can supply,
at
nominal
cost,
a
special
Index
Wheel
Holder
illustrated
tn
lower
section
of
Fig.
30

Advertisement

Table of Contents
loading