9.3 BASIC MACHINE OPTIONS DISASSEMBLY/REASSEMBLY PROCEDURES

9.3.1 DISASSEMBLING/REASSEMBLING THE HORIZONTAL MAGNETIC DEVICE
AND MICR ASSEMBLY
- Remove the printer case (section 9.2.1)
- Lift the entire mechanical assembly frontwards off the base of the printer and partly tilt it so as to
have access to the connectors on the magnetic device board (1)
- Detach the connectors of the horizontal magnetic device assembly from the magnetic device board
- Remove the two screws (2) that secure the assembly to the printer frame and remove the option.
1
Note:
Proceed with adjustment 8.2.4 (Frame Assembly Positioning) during reassembly.
9-18
2
Fig. 9-17
683311W