Panasonic WH-SDF09C3E8 Service Manual page 65

Air to water heat pump
Hide thumbs Also See for WH-SDF09C3E8:
Table of Contents

Advertisement

c. After finish, install back the Overload protector following the reverse order of step a & b.
7
External water filter (field supply)
Clean the external water filter in regularly basic.
External water filter is located inside the tube connector which is before water inlet connector of indoor
o
unit (indicated with "WATER IN"). (Refer to figure below)
Use spanner to detach the tube connector nut.
o
Take out the filter carefully so that not deforms it shape.
o
Use tap water only to wash the residue on the filter. If necessary, gently use soft brush only to clean the
o
hard dirt.
After clean, put it back to the original location and tighten the nut connection with torque wrench.
o
65