Standard models

The following table lists the standard models.
Table 2. Standard models
MTM*
Intel Xeon processor†
(2 maximum)
Models announced January 2014
5466-A2x
1x E5-2603 v2 4C 1.8GHz
10MB 1333MHz 80W
5466-A4x
1x E5-2603 v2 4C 1.8GHz
10MB 1333MHz 80W
5466-B2x
1x E5-2609 v2 4C 2.5GHz
10MB 1333MHz 80W
5466-C2x
1x E5-2620 v2 6C 2.1GHz
15MB 1600MHz 80W
5466-C4x
1x E5-2620 v2 6C 2.1GHz
15MB 1600MHz 80W
5466-D2x
1x E5-2630L v2 6C 2.4GHz
15MB 1600MHz 60W
5466-F2x
1x E5-2660 v2 10C 2.2GHz
25MB 1866MHz 95W
5466-F4x
1x E5-2660 v2 10C 2.2GHz
25MB 1866MHz 95W
5466-G2x
1x E5-2695 v2 12C 2.4GHz
30MB 1866MHz 115W
* x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is
5466-A2G, and the US MTM is 5466-A2G). Ask an IBM representative for specifics.
† Processor detail: Processor quantity and model, number of cores, core speed, L3 cache, memory speed, and
TDP.
§ For models A2x, A4x, and B2x, the standard DIMM is rated at 1600 MHz, but operates at up to 1333 MHz to
match the processor memory speed. Conversely, for models F2x, F4x, and G2x, the processor memory speed is
rated at 1866 MHz, but operates at up to 1600 MHz to match the rated speed of the installed DIMM. Actual memory
speed maximums depend on several factors, as described in "Memory options".
For more information about the standard features of the server, see the "Specifications" section.
IBM System x3650 M4 BD Product Guide
Memory
RAID
Drive
(RDIMMs)
bays
1x 8GB
M5110
12x 3.5"
1600MHz§
HS / 14
1x 8GB
M5110
12x 3.5"
1600MHz§
HS / 14
1x 8GB
M5110
12x 3.5"
1600MHz§
512MB Flash
HS / 14
1x 8GB
M5110
12x 3.5"
1600MHz
512MB Flash
HS / 14
1x 8GB
M5110
12x 3.5"
1600MHz
512MB Flash
HS / 14
1x 8GB
M5110
12x 3.5"
512MB Flash
HS / 14
1600MHz
1x 8GB
H1110,
12x 3.5"
1600MHz§
N2115
HS / 14
1x 8GB
H1110,
12x 3.5"
N2115
1600MHz§
HS / 14
1x 8GB
M5110 1GB
12x 3.5"
1600MHz§
Flash
HS / 14
Drives
Onboard
I/O
NIC
slots
(std /
max)
Open
3x GbE,
3 / 3
bay
2x 10 GbE
Open
3x GbE
3 / 3
bay
Open
3x GbE
3 / 3
bay
Open
3x GbE,
3 / 3
bay
2x 10 GbE
Open
3x GbE
3 / 3
bay
Open
3x GbE,
3 / 3
bay
2x 10 GbE
Open
3x GbE,
3 / 3
bay
2x 10 GbE
Open
3x GbE
3 / 3
bay
Open
3x GbE
3 / 3
bay
Optical
Power
drive
supply
(std /
max)
None
1x 750W
HS / 2
None
1x 750W
HS / 2
None
1x 750W
HS / 2
None
1x 750W
HS / 2
None
1x 750W
HS / 2
None
1x 750W
HS / 2
None
1x 900W
HS / 2
None
1x 900W
HS / 2
None
1x 900W
HS / 2
8