Performing Calibration

If labels with gaps/black marks are in use, perform media calibration
before printing to make printer index correctly.
1. Properly install labels.
2. Power off the printer.
3. Press and hold the FEED button then turn on power; do not
release the button until printer starts to feed labels.
4. Then, press FEED button once or twice to check that labels
are correctly indexed.
Note: You must always carry out calibration when changing
media. Failure to do so will result in improper
detection by the label sensor.

Printing a Configuration Report

The Configuration report, also known as the Self-Test report, can
work as a printer diagnosis tool. Steps to print a Configuration report
are listed below:
1. Press the Power Button to turn off the printer.
2. Make sure the Battery is installed and media is loaded.
3.
Press and hold the Feed Button, and then press the Power
Switch to turn on the printer.
4.
After printer starts to print, release the Feed Button.
5.
Wait until printer finishes printing, then press the Power Switch
or Feed Button to resume normal printing mode.
AME-3230 & AME-3230B User's Manual
33
Sample printout of Configuration (Self-Test):
AME-3230 & AME-3230B User's Manual
Firmware Version
Firmware version
Printed label length
Flash memory capacity
RS-232 parameters
Media type setting
Standby duration (in minutes)
Bluetooth PIN code
34