Technical Specifications; Electrical Connection - John Lewis JLBIDW 901 Instruction Manual

Compact dishwasher
Table of Contents

Advertisement

Installation

Technical specifications

Dimensions

Electrical connection:

Voltage
Overall power
Fuse
Water supply pressure
Capacity
Electrical connection
Any electrical work required to install this appliance should be
carried out by a qualified electrician or competent person.
WARNING:THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability should this
safety measure not be observed.
Before switching on, make sure the electricity supply voltage is the
same as that indicated on the appliance's rating plate.The rating
plate is located on the side of the dishwasher's door.
The plug moulded onto the lead incorporates a 13amp BSI362
fuse. Only ASTA or BSI fuses should be used.
To isolate the dishwasher from mains, remove the mains plug.
If the plug that is fitted to your appliance is not suitable for the
socket, it must be cut off and the appropriate plug fitted.
Important
The wires on the mains lead are coloured in accordance with the
following code:
Green and Yellow
- Earth
Blue
- Neutral
Brown
- Live
Width
Height
Max depth
Max depth with open door
Information on the electrical connection is given on the rating plate on the inner
edge of the dishwasher's door.
Minimum
Maximum
If you fit your own plug, the colours of the wires in the mains lead
of your appliance may not correspond with the markings
identifying the terminals in your plug.
Proceed as follows:
1. Connect the Green and Yellow (earth) wire to the terminal
in the plug which is marked with the letter "E" or the earth
symbol
or coloured green and yellow.
2. Connect the Blue (neutral) wire to the terminal in the plug
which is marked with the letter "N" or coloured black.
3. Connect the Brown (live) wire to the terminal in the plug
which is marked with the letter "L" or coloured red.
4. Upon completion there must be no cut, or stray strands of
wire present and the cord clamp must be secure over the
outer sheath.
The plug must not be used if the fuse cover/carrier is lost.The
cover/carrier is indicated by the coloured insert at the base of
the plug.
A replacement cover/carrier must be obtained from your local
Service Force centre. Please contact our extended warranty
administrators on 0870 0107887 who will give you details for
your local Service Force centre.
6
44.6 cm
81.8 - 87.8 cm
55.5 cm
114 cm
0,05 MPa (0,5 bar)
0,8 MPa (8 bar)
9 place settings