KERN RXB Operating Instruction

Price computing scale

Advertisement

Quick Links

Operating instruction

Price computing scale
KERN RXB
Version 1.2
11/2010
GB
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
RXB-BA-e-1012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RXB and is the answer not in the manual?

Questions and answers

Summary of Contents for KERN RXB

  • Page 1: Operating Instruction

    KERN & Sohn GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www.kern-sohn.com Operating instruction Price computing scale KERN RXB Version 1.2 11/2010 RXB-BA-e-1012...
  • Page 2: Table Of Contents

    KERN RXB Version 1.2 11/2010 Operating instruction Price computing scale Table of Contents Technical data __________________________________________________ 4 Declaration of conformity ________________________________________ 6 Appliance overview _____________________________________________ 7 Overview of display _______________________________________________ 9 3.1.1 Display weight _______________________________________________________ 10 3.1.2 Display basic price ____________________________________________________ 10 3.1.3...
  • Page 3 10.2 Menu overview __________________________________________________ 20 10.3 Adjustment _____________________________________________________ 20 Verification__________________________________________________ 22 11.1 Adjustment key and seals _________________________________________ 23 Service, maintenance, disposal _________________________________ 24 12.1 Cleaning _______________________________________________________ 24 12.2 Service, maintenance _____________________________________________ 24 12.3 Disposal________________________________________________________ 24 Instant help _________________________________________________ 25 RXB-BA-e-1012...
  • Page 4: Technical Data

    1 Technical data KERN RXB 3K1M RXB 3K1HM RXB 6K2M RXB 6K2HM Readability (d) Weighing range 3 kg 3 kg 6 kg 6 kg (max) Minimum load 20 g 20 g 40 g 40 g Verification value Verification class Reproducibility Linearity ±...
  • Page 5 KERN RXB 15K5M RXB 15K5HM RXB 30K10M 30K10HM Readability (d) 10 g 10 g Weighing range 15 kg 15 kg 30 kg 30 kg (max) Minimum load 100 g 100 g 200 g 200 g Verification value Verification class Reproducibility Linearity ±...
  • Page 6: Declaration Of Conformity

    Electronic Balance: KERN CXB/RXB/CXP EU Directive Standards 2004/108/EC EN 61326-1:2006 EN 61000-3-2:2006 EN 61000-3-3:1995/A2:2005 2006/95/EC EN 61010-1:2001 Date: 12.07.2010 Signature: KERN & Sohn GmbH Management KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 Fax +49-[0]7433/9933-149, E-Mail: info@kern-sohn.com, Internet: www.kern-sohn.com RXB-BA-e-1012...
  • Page 7: Appliance Overview

    3 Appliance overview Models without vertical display: Bubble level Secondary display on customer side: Battery compartment Connection network cable ON/OFF switch RXB-BA-e-1012...
  • Page 8 Models with post-mounted display: Post-mounted display, backlit, revolvable Bubble level Battery compartment Connection network cable ON/OFF switch RXB-BA-e-1012...
  • Page 9: Overview Of Display

    3.1 Overview of display Operator display balance: Weight Basic price 0.00 0.000 0.00 Loading status display Sales price Secondary display on customer page: Weight Basic price Sales price RXB-BA-e-1012...
  • Page 10: Display Weight

    The arrows next to the symbols show: €/kg Basic price in €/kg €/100 g Basic price in €/100 g 3.1.3 Display sale price Here the sales price is displayed in Euro [€]. The arrows next to the symbols show: Stored basic price//FIX mode "on" RXB-BA-e-1012...
  • Page 11: Keyboard Overview

    -key, then 2 = basic price in €/100 g • Delete total basic price • Delete last input of basic price • Zero key, range (±2 % max) • Taring key • Store set basic price • FIX-Mode „on“/“off“ RXB-BA-e-1012...
  • Page 12: Basic Information (General)

    The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. 4.3 Warranty Warranty claims shall be voided in case •...
  • Page 13: Monitoring Of Test Resources

    Infor- mation is available on KERN’s home page (www.kern-sohn.com with regard to the monitoring of balance test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and balances may be...
  • Page 14: Unpacking, Setup And Commissioning

    7.2 Unpacking Carefully remove the balance from the packaging, remove plastic cover and setup balance at the intended workstation. 7.2.1 Setup Level balance with foot screws until the air bubble of the water balance is in the pre- scribed circle. RXB-BA-e-1012...
  • Page 15: Scope Of Delivery

    In the event that the balance cannot be reset to zero with an applied weight, this range has been exceeded (± 0,2 % max). To reset the balance to zero, press key . A triangle [ ] pops up next to the [ a ] symbol on the display. RXB-BA-e-1012...
  • Page 16: Operation

    0.000 0.00 0.00 about 2 sec. The zero display of the balance appears in all three display windows. For additional weighing processes re-enter the basic price / tare value. RXB-BA-e-1012...
  • Page 17: Fix Mode - Storing A Basic Price

    Deleting stored basic price: Press CE key Deleting stored tare value: Press TARE key Exit FIX mode: Press FIX key, [ ] next to [FIX] is extinguished. RXB-BA-e-1012...
  • Page 18: Display Background Illumination

    The set mode will remain after the balance was turned off. Method 2: Press -key for 2 sec, acoustic signal sounds 3 times. This procedure can be used to switch between auto backlight and backlight off. RXB-BA-e-1012...
  • Page 19: Function Menu

    Keep pressing down the key until the balance counts down to zero and the first function F0 appears. Further functions F0 – F8 are selected by pressing the TARE key. Exit menu by pressing the key, balance returns to weighing mode. RXB-BA-e-1012...
  • Page 20: Menu Overview

    To receive accurate measuring values it is also recommended to adjust the balance periodically in weighing operation. RXB-BA-e-1012...
  • Page 21 • The balance returns automatically into weighing mode. An error message will appear on the display should a adjustment error occur or should the adjust- ment weight be incorrect. Turn balance off, then restart it and repeat the ad- justment process. Notice: Again throw the verification switch for calibrated balances. RXB-BA-e-1012...
  • Page 22: Verification

    The weighing result of the balance is outside the error limit. Therefore, in • regular intervals load balance with known test weight (ca. 1/3 of the max. load) and compare with displayed value. The reverification deadline has been exceeded. • RXB-BA-e-1012...
  • Page 23: Adjustment Key And Seals

    11.1 Adjustment key and seals When verification of a scale is finished, the positions indicated on the scale are sealed. Verification of a scale without a seal is invalid. Position of seals: SEAL SEAL SEAL RXB-BA-e-1012...
  • Page 24: Service, Maintenance, Disposal

    Spilled weighing goods must be removed immediately. 12.2 Service, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. Before opening, disconnect from power supply. 12.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
  • Page 25: Instant Help

    • Great fluctuations in temperature. • Electromagnetic fields / static charging (choose different location/switch off inter- fering device if possible) Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. RXB-BA-e-1012...

Table of Contents