Checking The Drives For Data Consistency - Asus RS720-E6 User Manual

2u rackmount server
Table of Contents

Advertisement

3.
After selecting the drive to rebuild, press <F10>. When prompted, press <Y>
to rebuild the drive.
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Rebuilding Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)?
Port # 1 DISK
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
4.
When rebuild is complete, press any key to continue.
6.2.5

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual
drive. The utility can automatically detect and/or detect and correct any differences in
data redundancy depending on the selected option in the Objects > Adapter menu.
The Check Consistency command is available only for virtual drives included
in a RAID 1 or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the Check Consistency command
From the Management Menu, select Check Consistency, and then press
1.
<Enter>.
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
ASUS RS720-E6/RS12
BIOS Version
A.08.09161344R
REBUILD - PHYSICAL DRIVES SELECTION MENU
PORT #
0
ONLIN A00-00
1
RBLD A00-01
77247MB
HDS728080PLA380
BIOS Version
A.08.09161344R
CC Of VD(s)
PF20A60A
6-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs12-e3Rs720-e6/rs12