17.2. Sensible Capacity Chart

CS-RE18JKE CU-RE18JKE
Indoor wet
bulb temp.
TC
17.0qC
4.96
19.0qC
19.5qC
5.45
22.0qC
5.94
CS-RE24JKE CU-RE24JKE
Indoor wet
bulb temp.
TC
17.0qC
6.75
19.0qC
19.5qC
7.41
22.0qC
8.07
TC
-
Total Cooling Capacity (kW)
SHC
-
Sensible Heat Capacity (kW)
IP
-
Input Power (kW)
30
35
SHC
IP
TC
SHC
3.76
1.35
4.64
3.61
5.00
3.94
1.37
5.09
3.78
4.08
1.40
5.55
3.93
30
35
SHC
IP
TC
SHC
5.11
1.94
6.30
4.90
6.80
5.35
1.98
6.92
5.14
5.55
2.01
7.54
5.34
Outdoor Temp. (qC)
40
IP
TC
SHC
1.45
4.31
3.47
1.47
1.48
4.74
3.64
1.50
5.16
3.79
Outdoor Temp. (qC)
40
IP
TC
SHC
2.09
5.86
4.71
2.12
2.13
6.44
4.95
2.17
7.02
5.15
89
46
IP
TC
SHC
IP
1.55
3.92
3.29
1.67
1.58
4.31
3.47
1.70
1.61
4.69
3.61
1.73
46
IP
TC
SHC
IP
2.23
5.33
4.48
2.41
2.28
5.85
4.71
2.45
2.32
6.38
4.91
2.50
Indoor 27qC/19qC
Outdoor 35qC/24qC