11.3. Outdoor Unit

11.3.1. Install the Outdoor Unit
• After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram.
1. Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø10 mm).
2. When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand firmly with bolt or
nails.
11.3.2. Connecting the Piping
Connecting the Piping to Indoor Unit
Please make flare after inserting flare nut (locate at joint portion
of tube assembly) onto the copper pipe.
(In case of using long piping).
Connect the piping
• Align the center of piping and sufficiently tighten the flare nut
with fingers.
• Further tighten the flare nut with torque wrench in specified
torque as stated in the table.
Connecting the Piping to Outdoor
Decide piping length and then cut by using pipe cutter. Remove
burrs from cut edge. Make flare after inserting the flare nut
(located at valve) onto the copper pipe.
Align center of piping to valves and then tighten with torque
wrench to the specified torque as stated in the table.
Model
A
RE18***
612.5 mm
RE24***, RE28***
613 mm
Do not over tighten, over tightening cause gas leakage.
Piping size
1/4" (6.35 mm)
3/8" (9.52 mm)
1/2" (12.7 mm)
5/8" (15.88 mm)
3/4" (19.05 mm)
32
B
C
D
131 mm
19 mm
383 mm
131 mm
16 mm
360.5 mm
CAUTION
Torque
[18 N m (1.8 kgf.m)]
[42 N m (4.3 kgf.m)]
[55 N m (5.6 kgf.m)]
[65 N m (6.6 kgf.m)]
[100 N m (10.2 kgf.m)]