Compressor Will Not Stop After Sufficient; Condenser Fan Motor Not Operating; Dispensing Valves; Water Or Syrup Leaking From Nozzle After Actuation - ICI TOPPER Installation And Service Manual

Table of Contents

Advertisement

Note: Ice bank freezes from bottom of evaporator upward. A refrigerant leak or insufficient charge
might show ice at bottom and not at top of evaporator.
Compressor will
1.
not stop after
sufficient ice
2.
bank is
produced
Note: During overload protector shut off condenser fan motor will continue to work. Otherwise,
troubleshooting condenser fan motor problems is the same as "Compressor does not operate",
paragraph in addition to the following.
Condenser fan
1.
motor not
operating
2.
3.

DISPENSING VALVES

Water or syrup
1.
leaking from
nozzle after
actuation
No water, no
1.
syrup being
dispensed from
2.
valve
3.
4.
5.
6.
Ice bank control capillary tube
kinked or broken.
Ice bank control stuck in closed
position.
Electrical cord loose or
disconnected from condenser fan
motor or compressor terminals.
Fan blade obstructed.
Inoperative condenser fan motor.
Foreign debris under plunger seat
or bent, creased stem.
No electrical power.
Frozen water bath.
Pinched or crimped lines.
Broken sub-miniature switch.
Bad transformer.
Disconnected wire.
1.
Replace ice bank control.
2.
Replace ice bank control.
1.
Tighten connections or replace
cord.
2.
Remove obstruction.
3.
Replace condenser fan motor.
1.
a. Disconnect syrup or water
from affected valve.
b. Relieve pressure by
activating valve.
c. Remove E-623 nut from
syrup or water solenoid.
d. Remove e-525 coil assembly
from e-527 stem.
e. Remove E-527 stem from
valve body.
should be taken not to dent
smooth E-527 wall.
f.
Valve stem seat should be
inspected for any foreign
debris. If debris is found
remove at this time, also
check E-730 stem.
Movement should be
unrestricted and free.
g. Inspect E-730 plunger seat
for damage, replace if
damaged.
h. Reassemble by reversing
above procedure.
1.
Plug power cord into electrical
box. Check line voltage.
2.
See "Frozen water bath".
3.
Repair defective line.
4.
Replace defective switch.
5.
Replace defective transformer.
6.
Attach disconnected wire.
6-3
Note: care

Advertisement

Table of Contents
loading

This manual is also suitable for:

Topper-j

Table of Contents