ACCESSORIES WIRING DIAGRAMS
OUTDOOR UNIT
FOSSIL FUEL KIT
FFK02A
INDOOR THERMOSTAT
FURNACE
1. Thermostat requirements:
a. Must be minimum 1 stage cool and 2 stage heat.
b. Must continuously energize O terminal in cooling mode.
c. Must not continuously energize O when in Automatic changeover mode.
d. Should have adjustable heat anticipator(s).
e. Must automatically bypass compressor heat (W1/Y1) when in the emergency heat mode.
f. Emergency heat mode must not continuously energize the E terminal when in emergency heat
mode.
Amana Thermostat THSADC1H2BA shown.
The following Amana thermostats also meet the above requirements:
THSMDC1H2BA
THPADC1H3BA
THPMFC1H2BA
2. If W1 terminal present on room thermostat, jumper W1 to Y (or Y1).