Amana VTC Product Specifications
Amana VTC Product Specifications

Amana VTC Product Specifications

Vertical terminal air conditioner and heat pump 3/4 ton through 2 tons

Advertisement

P
S
RODUCT
PECIFICATIONS
¾ Ton through 2 Tons
SS-VTAC
A
IR
No other unit in the industry offers so many
extras already built in as standard on every
unit. Don't settle for anything less than the
®
Amana
brand Standard Ad van tage!
Evaporator Coil Freeze Pro tec tion
Compressor Restart Delay
Low Ambient Lock-out
Manual Outside Air Damper
Wall-mount Thermostat
Electrical Disconnect
Random Unit Restart
Front Desk Control
Fan On/Off Delay
High-effi ciency Operation
Quiet Operation
Reliability and Durability
C
H
EAT
E
LECTRIC
www.goodmanmfg.com
VTC / VTH
V
T
ERTICAL
ERMINAL
C
H
P
ONDITIONER AND
EAT
: 8,350 - 23,800 BTU/
OOLING
P
: 8,120 - 22,800 BTU/
UMP
H
: 5,100 - 34,100 BTU/
EAT
U
3.5 COP
P TO
UMP
H
H
H
5/08
Supersedes 12/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VTC and is the answer not in the manual?

Questions and answers

Summary of Contents for Amana VTC

  • Page 1 VTC / VTH ERTICAL ERMINAL ONDITIONER AND RODUCT PECIFICATIONS No other unit in the industry offers so many extras already built in as standard on every unit. Don’t settle for anything less than the ® Amana brand Standard Ad van tage! •...
  • Page 2 RODUCT PECIFICATIONS EATURES • Front Desk Control • Compressor Restart Delay – (3 min.) Enable or disable each unit from the front desk to save energy Ensures that system pressure equalizes before the system re- used to con di tion unoccupied rooms. starts, so compressor life is extended.
  • Page 3: Cooling Performance Data

    RODUCT PECIFICATIONS VTC M —C ODEL PECIFICATIONS OOLING LECTRIC (208/240 -1 P LECTRICAL Electric Heat Data Blower Data Condenser Data Minimum Maximum Circuit Circuit Total Heating Evaporator Condenser Ship Model BTU/h Compressor Ampacity Protection Amps Motor Motor Weight 240V 208V...
  • Page 4: Blower Data

    RODUCT PECIFICATIONS VTC M —C ODEL PECIFICATIONS OOLING LECTRIC CONT LOWER Motor CFM vs. External Static Pressure Model Speed1 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 Connection High VTC093B High VTC123B High VTC183B High 1,030 1,000 VTC243B Notes: (1) VTC12, 18- and 24-blower motors are factory-wired for medium (cooling) and low (heating) fan operation.
  • Page 5: Electrical Data

    RODUCT PECIFICATIONS VTH M —C ODEL PECIFICATIONS OOLING LECTRIC (208/240 -1 P LECTRICAL Electric Heat Data Blower Data Condenser Data Minimum Maximum Total Ship Circuit Circuit Evaporator Compres- BTU/h Heating Motor Ampacity Protection Motor Amps (lbs) 240V 208V 240V 208V 240V 208V AMPS RLA LRA FLA 208V 230V 208V 230V...
  • Page 6 RODUCT PECIFICATIONS IMENSIONAL DUCT OPENING (C) 6-1/8 ELEMENT FILTER RETURN BLOWER MOTOR DISCONNECT CONDENSER ELECTRICAL OUTLET KNOCKOUT VOLTAGE 41-1/4 CONDENSER INLET VTC/VTH 09, 12, 18 6½ 6½ 6½ x 10 VTC/VTH 24 10 x 10 www.goodmanmfg.com SS-VTAC...
  • Page 7 RODUCT PECIFICATIONS CCESSORIES • Wall-mounted Low-voltage Thermostat Easily con trols the unit. Low-voltage wires exit the left side of the cabinet. (pg. 8) NIT WITH NSTALLED LEEVE AND LUSH STYLE OUVER • “Flush Style” Architectural Louver Attaches to the outside of the wall sleeve for a fl ush appearance. Louvers recess into the wall sleeve;...
  • Page 8 RODUCT PECIFICATIONS CCESSORIES CONT • Wall-mounted Low-voltage Thermostat* Straight Cool/ Digital cool - off - 1246001 Easily con trols the unit. Low-voltage wires exit the left side of Hydronic Chassis heat, auto - on the cabinet. Heat Pump Digital cool - off - 1246003 * Available for straight cool/hy dron ic chassis and heat pump chassis.
  • Page 9 VTC/VTH cab i net. A mesh screen is in stalled in side the vent pipe, and a met al plate on the side of the cab i net cov ers the open ing of the vent pipe.
  • Page 10: General Assembly

    RODUCT PECIFICATIONS ENERAL SSEMBLY Rough-In Di men sions 44”H x 21 5/8”W Ap prox i mate Fastener Locations Electrical Dis con nect Filter Sleeve Seal Rear Access Panel Wall Sleeve Drain 3/4” MPT Outside Electrical Service Knock-out www.goodmanmfg.com SS-VTAC...
  • Page 11: Wall Sleeve

    RODUCT PECIFICATIONS NSTALLATION NSTALLATION Notes: Grille 1. Sleeve rough-in opening is 44” (H) x 21-5/8” width: 22" 2. Bottom of opening should be approximately 6” above fl oor level. Unit must line up 3. Minimum 3” clearance is required on all sides with door opening of the unit.
  • Page 12: Guide Specifications

    U.L. regulations, where necessary. Hydronic Heat Units — Required for heating functions in- Amana is a trademark of Maytag Corporation and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality ®...