Viessmann Vitodens 200 WB2 Series Technical Data Manual page 45

Gas-fired wall-mounted condensing boiler 25 to 230 mbh/7 to 67 kw multi-boiler installation 344 to 920 mbh/
Hide thumbs Also See for Vitodens 200 WB2 Series:
Table of Contents

Advertisement

System Layout 8
Vitodens 200 (model WB2 11-44 and up) with...
– DHW storage tank
– low-loss header
– one heating circuit with mixing valve
TPV
PRV
O
Y
Y
Alternate locations
of expansion tank
Please note!
The use of a low-loss header is
recommended if the water flow rate is less
than 1.3 GPM / 300 ltr/h or more than 15.4
GPM / 3500 ltr/h.
The low-loss header is available as
accessory part.
See page 34 in this manual for details on
the low-loss header.
Model No.
Max. flow rate
(GPM/ltr/h)
Vitodens 200,
WB2 11-44
15.4/3500
WB2 15-60
15.4/3500
AV
M
~
I
P
The radiator heating circuit is supplied by a
circulation pump (field supplied). An
expansion board (optional) must be ordered
from Viessmann to control this pump.
The underfloor heating circuit is supplied by
a circulation pump installed on site which is
controlled by the accessory kit.
The DHW circulation pump is field supplied.
H1
H2
Installation Examples
AV Air vent
PRV Pressure relief valve
TPV Temperature and pressure relief
valve
Vitodens 200 gas-fired condensing
boiler with programming unit for
weather-responsive operation
Outdoor temperature sensor of
control unit for weather-responsive
operation
Remote control
Primary pump (boiler circuit, field
supplied) with low-loss header only
Underfloor heating circuit
Radiator heating circuit
Mixing valve temperature sensor
Heating circuit pump (field supplied)
H1
Heating circuit pump (field supplied)
H2
I
Accessory kit for heating circuit with
mixing valve
Low-loss header
Viessmann temperature sensor for
low-loss header
DHW circulating pump (field supplied)
DHW storage tank
O
DHW tank temperature sensor
P
Expansion tank
IMPORTANT
Pumps
and
must pump into the
Vitodens 200 boiler (as illustrated).
45