Viessmann Vitodens 200 WB2 Series Technical Data Manual page 24

Gas-fired wall-mounted condensing boiler 25 to 230 mbh/7 to 67 kw multi-boiler installation 344 to 920 mbh/
Hide thumbs Also See for Vitodens 200 WB2 Series:
Table of Contents

Advertisement

Venting Option
Single Wall Venting Option
Please note that there is no basic vent kit available for this vertical vent system.
See product literature supplied by manufacturer for available component parts.
24
Coaxial vent pipe adaptor (comes
pre-installed on model WB2-44/60)
IMPORTANT
For Vitodens 200, WB2 models 6-24C,
6-24 and 8-32, the vent pipe adaptor
must be ordered with the boiler.
Vent pipe adaptor (coaxial>single-wall)
Elbow, 90°
*1
Straight pipe
Elbow, 45°
Suspension band / hanger
Wall band
Vent termination coupling
(c/w bird screen)
Flashing and storm collar
*1
Available in different lengths.
For more detailed information on
component parts see product literature
supplied by special venting manufacturer.
Note:
The Vitodens boiler has passed the zero
inches vent clearance to combustibles
testing requirements dictated by the
Harmonized Standard ANSI Z21.13. CSA
4.9.2000 and therefore is listed for zero
clearance to combustibles when vented
with a single wall special venting system
(AL-29-4C material). The zero inches vent
clearance to combustibles for the Vitodens
boiler supercedes the clearance to
combustibles listing that appears on the
special venting system label.
IMPORTANT
A masonry chimney flue may be used to
route the venting system only if no other
appliance is vented in the same flue.