Parts Listing - IBM TotalStorage DS4000 Hardware Maintenance Manual

Hide thumbs Also See for TotalStorage DS4000:
Table of Contents

Advertisement

Table 23. Symptom-to-FRU index for FAStT200 and FAStT200 HA Type 3542 controller (continued)
One or more green LEDs off - Host Loop
One or more green LEDs off - Expansion Loop
Intermittent or sporadic power loss to the storage
server - Some or all CRUs
Unable to access drives on Drives and fibre channel
loop
Random errors on Subsystem
The Storage Manager client Enterprise Management
window sees each storage server controller as an
independent storage subsystem.
Note: If you cannot find the problem in Table 23 on page 44, test the entire system.

Parts listing

Figure 30 on page 46 and the following table provide a parts listing for the
FAStT200 and FAStT200 HA controllers.
1. Check if host managed hub or switch is on. Replace
attached devices that have failed.
2. Fibre channel cables
3. GBIC
4. RAID controller
1. Ensure drives are properly seated.
2. RAID controller
3. Drive
4. GBIC or fibre channel cable
1. Check the ac power source.
2. Reseat all installed power cables and power supplies.
3. Replace defective power cords.
4. Check for a Fault LED on the power supply, and replace
the failed CRU.
5. Midplane
1. Ensure that the fibre channel cables are undamaged and
properly connected.
2. RAID controller
1. Midplane
No drives are present in the storage server. Ensure that at
least one drive is present in the storage server so that it can
be configured properly.
One controller was replaced incorrectly. The controller
firmware versions probably failed to synchronize correctly.
To recover, perform the following steps:
1. Remove and reinsert the controller blade.
2. Wait 5 minutes.
3. Delete the controller entry with the incorrect firmware
version from the DS4000 Storage Manager Enterprise
Management window.
4. Add the controller back to the DS4000 Storage Manager
Enterprise Management window using the Add Device
menu option in the Enterprise Management window.
5. If the Storage Manager client Enterprise Management
window still shows each storage server controller as an
independent storage subsystem or a partially managed
device, repeat this procedure. If the problem still persists,
contact IBM support.
Chapter 7. FAStT200 Type 3542 and FAStT200 HA Type 3542
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents