Table 17. Symptom-to-FRU index for Type 3526 fibre channel RAID controller (continued)
Problem
Power Supply LED is off.
Power Supply CRU LEDs are on, but all other CRU
LEDs are off.
Parts listing
Figure 23 and the following table provide a parts listing for the type 3526 fibre
channel RAID controller.
Figure 23. Type 3526 fibre channel RAID controller parts list
Index
Fibre channel RAID controller (Type 3526)
1
350-W Power Supply
2
Rear Fan Assembly (Power Supply Fan)
3
Optical Cable - 5 Meters (option)
3
Optical Cable - 25 Meters (option)
4
Media Interface Adapter (MIA)
5
Frame Assembly with Midplane
6
Controller Assembly with 32 MB memory/128
MB cache
7
Battery Backup Assembly
8
Bezel Assembly
Action/FRU
1. Check and reseat power supply.
2. Check for overheating. Wait ten minutes for the power
supply CRU to cool down. See "Recovering from a power
supply shutdown" on page 22.
3. Power supply CRU
1. DC power harness
Chapter 6. Type 3526 Fibre Channel RAID Controller
1
FRU
01K6743
01K6741
03K9202
03K9204
03K9280
10L6981
10L6993
01K6742
10L7043
33