Symptom-To-Fru Index; Symptom-To-Fru Index For Fastt200 And Fastt200 Ha Type 3542 Controller - IBM TotalStorage DS4000 Hardware Maintenance Manual

Hide thumbs Also See for TotalStorage DS4000:
Table of Contents

Advertisement

Symptom-to-FRU index

Use the storage management software to diagnose and repair controller unit
failures. Use Table 23 also to find solutions to problems that have definite
symptoms.
See the PD maps in the IBM TotalStorage DS4000 Problem Determination Guide for
more detailed procedures for problem isolation.
Table 23. Symptom-to-FRU index for FAStT200 and FAStT200 HA Type 3542 controller
Problem Indicator
Amber LED on - Drive CRU
Amber LED on - Fan CRU
Amber LED on - RAID controller Fault LED
Amber LED on - Expansion port Bypass LED
Amber LED on - Front panel
Amber LED on and green LED off - Power supply
CRU
Amber and green LEDs on - Power-supply CRU
All green LEDs off - All CRUs
Amber LED flashing - Drive CRUs
One or more green LEDs off - Power supply CRUs
One or more green LEDs off - All drive CRUs
One or more green LEDs off - Front panel
One or more green LEDs off - Battery
One or more green LEDs off - Cache active
44
IBM TotalStorage DS4000: Hardware Maintenance Manual
Action/FRU
1. Replace the drive that failed.
1. Replace the fan that failed.
1. If the RAID controller Fault LED is lit, replace the
RAID controller.
1. No corrective action needed if system is properly
configured and no attached expansion units.
2. Reattach the GBICs and fibre channel cables. Replace
input and output GBICs or cables as necessary.
3. Expansion unit
1. Indicates that a Fault LED somewhere on the storage
server has turned on. (Check for amber LEDs on CRUs).
1. Turn on all power supply power switches.
2. Check ac power.
1. Replace the failed power-supply CRU.
1. Check that all storage server power cords are plugged in
and the power switches are on
2. Check that the main circuit breakers for the rack are
turned on.
3. Power supply
4. Midplane
1. No corrective action is needed. (Drive rebuild or identity
is in process.)
1. Make sure that the power cord is plugged in and the
power-supply switches are turned on.
1. Midplane
1. Make sure that the cords are plugged in and power
supplies are turned on.
2. Midplane
1. Battery
1. Use the storage management software to enable the
cache.
2. RAID controller
3. Battery

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents