Clearances; Installation - Majestic fireplaces UV36RN Homeowner's Installation And Operating Instructions Manual

Vent-free gas fireplaces
Table of Contents

Advertisement

UV36RN/RP Vent-Free Gas Fireplaces
21¹⁄₈"
14¹⁄₂"
36"
2" Min. Clearance
to Mantel Leg
Min. 36"
36"
From Top
of Unit to
Ceiling
Fig. 4 UV36 framing dimensions.

Clearances

To ensure a safe installation, the following instructions
must be carefully observed.
1. Sidewall Clearances: Clearances from the side of
the fireplace opening to any combustible wall should
not be less than 2".
2. Ceiling Clearances: The ceiling height should not
be less than 36" from the top of the fireplace (Fig.
5a).
Mantel Clearances:
a. Mantel profile: The minimum distance above the
fireplace opening to combustible material project-
ing 1" (tile moldings, breast boards, etc.) is 13".
Combustible material projecting 6" (a mantel
shelf, for example) requires a minimum clearance
of 20¹⁄₄" above the fireplace opening. Required
clearance varies with the amount of projection.
(Fig. 5a)
The mantel profile must fall within the cross-sec-
tion shown in Figure 5a (with standard canopy)
or Figure 5b (if a AH3342 adjustable canopy is
used).
8
1/2"
1/2" Clearance
not Required
at This Point
14¹⁄₂"
Min.
36¹⁄₈"
10"
7"
4"
T143
1"
T143
framing dimension
13"
11/4/03 djt
12"
standard canopy
clearances
11/4/03 djt
b. With Canopy: The minimum distance above the
fireplace opening to combustible material project-
ing 1" (tile moldings, breast boards, etc.) is 9".
Combustible material projecting 6" (a mantel
shelf, for example) requires a minimum clearance
of 12" above the fireplace opening. Required
clearance varies with the amount of projection.
(Fig. 5b)
c. Heat resistant material: Any heat resistant mate-
rial suitable for a continuos operating temperature
of 120°C (248°F) must cover the wall surface di-
rectly above the fireplace opening and extend the
full width of the fireplace opening for a distance
of 9" above the opening of the fireplace. (Figs. 5a
and 5b)
d. Refer to Figure 6 for mantel leg clearances.
NOTE: Due to the continuous heat output of a
Vent Free Fireplace, occasional discoloration or
peeling of paint and varnish materials may be
noticed directly above the fireplace opening.
Combustibles
Allowed in
Shaded Area
Combustible
Header
26"
Standoff
Spacer
21¹⁄₂"
17¹⁄₄"
Fireplace
Top Face
*Ceiling height is the minimum height of the room ceiling in front of
the fireplace measured from the top front edge of the fireplace.
Fig. 5a Minimum mantel clearance with standard canopy.
T144
Ceiling*
Min. 36" From Top
of Unit to Ceiling
10"
7"
4"
1"
21¹⁄₂"
Combustible
17¹⁄₄"
Face Wall
12" 13"
Noncombus-
tible to Top of
Standoff
Canopy
Top of Screen
Top of Fireplace
Frame
Opening
Canopy Installation
(Top View)
Hex Head Screws
Canopy
26"
T144
20007436