REPLACEMENT INSTRUCTIONS

Caution: Be sure to turn the ON/OFF switch to the "OFF " position and disconnect the
power cord from the wall outlet before replacing any of the parts below.
REPLACING THE FLAT BELT
Remove the bottom plate.
1
(refer to page 14)
Lift out the agitator assembly,and then remove the flat belt from the motor shaft and
2
the agitator pulley.
Agitator Assembly
3
Place a new flat belt onto the motor shaft and pulley.
Flat Belt
Pulley
4
Holding two ends of the agitator to place the agitator assembly into the grooves by in the
nozzle head, making sure that the new flat belt slides securely into the guide.
5
Reattach the bottom plate
(refer to page 14)
Motor Shaft
Flat Belt
Motor Shaft
Flat Belt
Brush Holder
Groove
Caution:
Install the flat belt so that it has
no twists in it, and so that all
components turn smoothly.