Dimensions; Vent Specifications; Serial Number Label Location; Locating Your Stove - Quadra-Fire 2100 Millennium Owner's Manual

Advanced combustion technology (act) wood stove
Hide thumbs Also See for 2100 Millennium:
Table of Contents

Advertisement

FRONT VIEW
21-3/8" (543mm)
7-7/16"
(189mm)
13-5/8" (346mm)
17.0" (432mm)
26-1/2"
(673mm)
15-1/2" (393mm)
S
ingle Wall: Six inch (6") (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built
chimney type UL103 HT* suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
Double Wall/Mobile Home: Six inch (6") (152mm) diameter, listed double wall air insulated connector pipe with listed
factory-built UL103 HT* Class "A" chimney, or a masonry chimney (Mobile Home must be equipped with a spark arrestor),
and the referenced clearances. Use only double-wall connector pipe, Dura-Vent DVL, Selkirk metalbestos DS or Security
DL double wall connector. or any listed double-wall connector pipe.
*In Canada must comply with CAN/ULC-S269 for the 650°C Factory-built chimney.
WHEN LOCATING YOUR STOVE consider safety, convenience, traffic flow, and the fact that the stove will need a chimney
and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and
floor protection, before actually beginning the installation. If you're not using an existing chimney, place the stove where
there will be a clear passage for a factory-built listed chimney through the ceiling and roof.
AVOID FIRE: Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must maintain
the designated air space clearance around the chimney. This space around a chimney is necessary to allow natural heat
removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE: Clearances
may only be reduced by means approved by the regulatory authority having jurisdiction.
WE RECOMMEND that a qualified building inspector and your insurance company representative review your plans before
and after installation.
250-6931C November 3, 2004
2100 ACT Millennium Wood Stove

DIMENSIONS

10-11/16"
(271mm)
C L
12-3/4"
(324mm)
9-3/8"
(238mm)

SERIAL NUMBER LABEL LOCATION:

ON BACK OF STOVE
VENT SPECIFICATIONS

LOCATING YOUR STOVE

SIDE VIEW
25-7/8" (657mm)
23-1/16" (332mm)
5-3/8"
(137mm)
C L
Back of the stove to glass
22.0" (559mm)
15-3/4" (400mm)
C L
3-3/8" (86mm)
R
Page 5