Wiring Of System - Dometic 620515.321 Installation Instructions Manual

Roof top air conditioner roof top heat pump
Hide thumbs Also See for 620515.321:
Table of Contents

Advertisement

FIG. 13
Gasket
Low Voltage Wires
Junction Box
h. Install the Romex connector in the junction box.
Ceiling
FIG. 14
Junction Box
Junction
Air Conditioner
i
Measure the ceiling thickness:
If the distance is 2" to 3" remove the
perforated tabs from the bottom duct only.
If the distance is 3" to 4" install ducts as
received.
If the distance is 4" to 6" (maximum thick-
ness), optional Duct and Bolt Kits are avail-
able:
Duct (Part No. 318556.000)
Bolts (Part No. 3100895.006)
FIG. 15
CENTER A /C
FROM BEL OW
Remote Sensor
Control Cables
Discharge Air
14-1/4" x 14-1/4" (±1/8")
GASKET
MEASURE
CEILING
THICKNESS
620515, 620525, 620526, 630515 & 630516 Installation Instructions
j.
Take the ceiling template and slide the lower
duct over the upper duct.
FIG. 16
k. Hold the ceiling template with one hand and with
the other, install the three 1/4" mounting bolts
through the template and into the base pan.
Finger-tighten the (3) bolts and check align-
ment. There should be an equal opening on
each side and the rear flange must be tight
against the roof opening.
EVENLY tighten the bolts to a torque of
40 to 50 inch pounds. This will com-
press the roof gasket to approximately
1/2". The bolts are self locking so over
tightening is not necessary.
If bolts are left loose there may not be an ad-
equate roof seal or if over tightened, damage
may occur to the air conditioner base or ceil-
ing template. Tighten to torque specifications
listed in this manual.
H. Wiring Of System
Reach up into the return air opening and pull the remaining
wires down. See FIG. 13.
1. Connection Of Low Voltage Wires
Disconnect the positive (+) 12 volt DC termi-
nal at the supply battery. Damage to equip-
ment could occur if the 12 volt DC is not shut
off.
a. Route Remote Temperature Sensor cable, if
applicable, and attach it to the connector that
matches its color protruding from the return air
opening.
8
CAUTION
CAUTION

Advertisement

Table of Contents
loading