(Troubleshooting) Other problems

SYMPTOM
1. Oven is dead.
Fuse is OK.
No display and no operation at all.
2. No display and no operation at all.
Fuse is blown.
3. Oven does not accept key
input(Program)
4. Fan motor turns on when oven is
plugged in with door closed.
5. Timer starts count down but no
microwave oscillation.
(No heat while oven lamp and fan
motor turn on)
6. Oven can program but timer does not
start countdown.
7. Microwave output is low. Oven takes
longer time to cook food.
8. Fan motor turns on and turntable
rotates when door is opened.
9. Oven does not operate and return to
plugged in mode as soon as start pad
is pressed.
10. Loud buzzing noise can be heard.
11. Heater does not turn on.
12. Oven stops operation during cooking.
CAUSE
1.
Defective circuit breaker
2.
The switch of circuit breaker is in "O" position
3.
Open or loose lead wire harness
4.
Open thermal cutout / thermistor
5.
Open low voltage transformer
6.
Defective DPC
1.
Shorted lead wire harness
2.
Defective primary latch switch (NOTE 1)
3. Defective short switch (NOTE 1)
4. Defective Inverter Power Supply (U)
NOTE 1:
All of these switches must be replaced at the same time.
Check continuity of power relay B (RY1)´s contacts (between 1 and 2) and if it has continuity,
replace power relay B (RY1) also.
1.
Key input is not in proper sequence
2.
Open or loose connection of membrane key
pad to DPC (Flat cable)
3. Shorted or open membrane key board
4. Defective DPC
1. Misadjustment or loose wiring of secondary
latch switch
2. Defective secondary latch switch
1.
Off-alignment of latch switches
2.
Open or loose connection of high voltage circuit
especially magnetron filament circuit
NOTE:
Large contact resistance will cause lower
magnetron
filament
voltage
magnetron to have lower output and/or be
intermittent.
3. Defective high voltage component
H.V. Inverter Power Supply (u)
Magnetron
4. Open or loose wiring of power relay B (RY1)
5. Defective primary latch switch
6. Defective DPC or power relay B (RY1)
1. Open or loose wiring of secondary latch switch
2. Off-alignment of secondary latch switch
3. Defective secondary latch switch
1. Decrease in power source voltage
2. Open or loose wiring of magnetron filament
circuit.(Intermittent oscillation)
3. Aging change of magnetron
1. Shorted primary latch switch
1. Defective DPC
1. Loose fan and fan motor
1. Open or loose wiring of heater
2. Defective heater
3. Defective power relay
4. Defective DPC
1. Open or loose wiring of primary and
secondary latch switch
2. Operation of thermal cutout
25
CORRECTIONS
Turn the switch of circuit breaker to "I" position.
Check fan motor if thermal cutout is defective.
Check adjustment of primary, secondary latch
switch and short switch including door.
Refer to operation procedure.
Refer to DPC troubleshooting.
Adjust door and latch switches.
Adjust door and latch switches.
and
cause
Check high voltage component according to
component test procedure and replace if it is
defective.
Refer to DPC troubleshooting
Consult electrician
Check grounding connector on escutcheon
base.
Adjust door and latch switches.