NN-CS596S
Discharging the high voltage capacitors
WARNING
There is high voltage present with high current capabilities
in the circuits of the primary and secondary windings, choke
coil and heat sink of the inverter. It is extremely dangerous
to work on or near these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit
including the filament voltage of the magnetron.
WARNING
Never touch any circuit wiring with your hand or with an
insulated tool during operation.
3.3.

Confirm before repair

1. Before repair or replacement of parts, ensure to take out
the water tank from microwave oven. Further more, use
drainage function, to drain the water remaining in the water
pipes and tubes into oven cavity.
2. Wipe up the oven cavity.
WARNING
Before beginning repair work, make sure that there is no
water in microwave oven, otherwise the water might invade
the electric parts and will cause short circuit even result in
electric shock.
3.4.

Part replacement

When any part or component is to be replaced, always ensure
that the power cord is removed from the wall outlet.
3.5.
When the 10A/15A fuse is
blown due to the operation of
the short switch
WARNING
When the 10A/15A 240V fuse is blown due to the operation
of the interlock monitor switch, replace all of the
components (primary latch switch, short switch and power
relay B (RY1)).
1. This
is
mandatory.
measurements" for the location of these switches.
2. When replacing the fuse, confirm that it has the
appropriate rating for these models.
3. When replacing faulty switches, be sure the mounting
tabs are not bent, broken or deficient in their ability to
hold the switches.
3.6.
Avoid inserting nails, wire etc.
through any holes in the unit
during operation
Never insert a wire, nail or any other metal object through the
lamp holes on the cavity or any holes or gaps, because such
objects may work as an antennaand cause microwave leakage.
Refer
to
"adjustments
3.7.

Confirm after repair

1. After repair or replacement of parts, make sure that the
screws of the oven, etc. are neither loosen or missing.
Microwave might leak if screws are not properly tightened.
2. Make sure that all electrical connections are tight before
inserting the plug into the wall outlet.
3. Check for microwave energy leakage. (Refer to procedure
for measuring microwave energy leakage).
CAUTION MICROWAVE RADIATION
USE CAUTION NOT TO BECOME EXPOSED TO
RADIATION FROM THE MICROWAVE MAGNETRON OR
OTHER PARTS CONDUCTING MICROWAVE ENERGY.
IMPORTANT NOTICE
The following components have potentials above 2000V
while the appliance is operated.
• • • • Magnetron
• • • • High voltage transformer (Located on inverter (U))
• • • • High voltage diodes (Located on inverter (U))
• • • • High voltage capacitors (Located on inverter (U))
Pay special attention to these areas.
When the appliance is operated with the door hinges or
magnetron installed incorrectly, the microwave leakage can
exceed more than 5mW/cm
very important to check if the magnetron and the door
hinges are correctly installed.
IMPORTANT NOTICE
After repair or replacement of parts, make sure that all
the water pipes and tubes are properly connected,
otherwise the water might invade the electric parts and
will cause short circuit even result in electric shock.
3.8.

Sharp edges

CAUTION
Please use caution when unpacking, installing or moving
the unit, as some exposed edges may be sharp to the touch
and cause injury if not handled with care.