Continuous Flow Icemaker 1400R Installation Instructions
Bin Control — Place ice around probe, unit should shut down in one minute. Remove ice from around probe, unit
should start in two minutes.
Figure 1. Icemaker Float Assembly
Water modulating valve (water cooled units only) — Opening point of condenser water modulating valve should
be set to maintain proper operating pressure in the refrigeration system high side. Closing point of valve should be
set low enough to close valve during compressor stand by periods. To raise, turn counterclockwise, to lower turn
clockwise.
NOTE: If any of these checks or adjustments cannot be achieved, refer to Service Manual or call for
factory assistance at 1-800-238-3600.