Cornelius CONTINUOUS FLOW ICEMAKER 1400R Installation Instructions

Continuous flow icemaker series

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS

C
F
ONTINUOUS
LOW
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
This manual covers unpacking and inspection, selecting location, installing unit, and preparing for operation.
The unit is a split system; it consists of a condensing unit, an icemaker and a line kit.
The condensing unit is an outdoor component; it contains the compressor, condenser, receiver and fan motor. It is
controlled by a low-pressure switch.
The icemaker is an indoor component; it contains two gear motors, two evaporators, two water level controls and
two bin thermostats. The bin thermostats control a liquid line solenoid.
Line Kit: precharged 3/8" liquid line and 3/4" suction line.
NOTE: In a rack refrigeration application, only the ice maker is required (condensing unit and line kit are
not used). Ice maker installed on a -23° F (-30.56° C) low state saturation temperature (14 psig sat-
uration pressure for R404A) requires the installation of one EPR valve, set at 20 psig downstream
of the common suction line of WCC-1400R unit. Approved EPR model is ORIT-6-0/50.
R
U
C
EMOVE
NITS
1. Keep unit in the upright position, remove carton and pallet from unit and inspect for damage.
2. Locate startup card either on outside of container or on plastic liner. Fill in proper information and send one
copy to factory, and other copy to distributor. Postage is prepaid.
C
R
ABINET
EMOVAL
Condensing Unit
Remove 19 screws and lift upward.
Icemaker
1. Front Panel – Remove 4 screws and pull forward.
2. Top Panel – Remove 4 screws and lift upward.
3. Side Panels – Remove 3 screws and pull forward.
4. Back Panel – Should not be removed.
P
REPARATION OF
Condensing Unit
The refrigeration system is air-cooled, it requires airflow, so a well-ventilated area should be chosen. A minimum of
4 feet must be maintained for air intake and exhaust.
Revision Date: March 18, 2014
© 2005-2014, Cornelius Inc.
I
S
CEMAKER
ERIES
ARTON
I
S
NSTALLATION
ITE
www.cornelius.com
Continuous Flow Icemaker 1400R Installation Instructions
1400R
- 1 -
Revision: D
Publication Number: 630460310INS

Advertisement

loading

Summary of Contents for Cornelius CONTINUOUS FLOW ICEMAKER 1400R

  • Page 1: Installation Instructions

    Ice maker installed on a -23° F (-30.56° C) low state saturation temperature (14 psig sat- uration pressure for R404A) requires the installation of one EPR valve, set at 20 psig downstream of the common suction line of WCC-1400R unit. Approved EPR model is ORIT-6-0/50. EMOVE...
  • Page 2 Continuous Flow Icemaker 1400R Installation Instructions Icemaker The unit can be installed either on an ice storage bin or ice dispenser using proper adapter kits. (Refer to sales literature for information.) The install kit provided with each icemaker and adapter kits will supply everything to locate unit correctly.
  • Page 3 Continuous Flow Icemaker 1400R Installation Instructions Bin Control — Place ice around probe, unit should shut down in one minute. Remove ice from around probe, unit should start in two minutes. Figure 1. Icemaker Float Assembly Water modulating valve (water cooled units only) — Opening point of condenser water modulating valve should be set to maintain proper operating pressure in the refrigeration system high side.