Multiple Heater Piping - State Water Heaters Standard Residential Gas Water Heater Service Handbook

Hide thumbs Also See for Standard Residential Gas Water Heater:
Table of Contents

Advertisement

RESIDENTIAL GAS, NON POWER VENTED, WATER HEATER
Residential Gas – continued
Condensation is a mild acid – it will corrode steel
Condensation
is usually noted when:
water dripping is heard (only) while the main burner is on,
there is "water" around the heater just after the heater has been operating,
there are small, black or red granules on the main burner or top of the heater or
corroded jacket or vent piping is noted.
If ...
any of the above conditions exist
Suggested Multiple Heater Water Piping Required For
State Water Heater
© 2004
SERVICE HANDBOOK
Proper Operation of Top Connect Models
TEMPERATURE/PRESSURE RELIEF VALVES
... then
raise the supply air temperature or
increase stored water temperature or
increase the size of the tank
You would not wish to lower combustion
efficiency – this would waste gas. Use
materials (stainless steel, PVC etc.) that
will not be affected by the condensation
Installed in accordance with local codes.
14
Technical Training Department
Ashland city, TN

Hide quick links: