St. Croix York Operation Manual

St. Croix York Operation Manual

Bay front pellet insert 45 lbs. hopper
Hide thumbs Also See for York:

Advertisement

Operation & Maintenance
ST. CROIX FEATURES .......................................................................................2
INSTALLATION.................................................................................................. 3
PREVENTING CHIMNEY FIRES .....................................................................3
SATISFACTORY PERFORMANCE................................................................. 3
Pellet Fuel ...............................................................................................................3
Add Corn to the Mix..............................................................................................3
OPERATING INSTRUCTIONS......................................................................... 3
Control Board Features.............................................................................4
Thermostat Function - How does it work? .............................................5
Pre-Lighting Instructions..........................................................................6
Lighting Your Stove ................................................................................. 6
Shutting the Stove off ............................................................................... 6
Diagnostic Features....................................................................................6
Safety Features ...........................................................................................7
Combustion Air Damper ...................................................................... 7-8
Flame Pattern Characteristics ..................................................................8
MAINTAINING THE STOVE ............................................................................9
Daily Maintenance ........................................................................... 10-11
Periodic Maintenance ...................................................................... 11-13
Yearly Maintenance ......................................................................... 13-14
SAFE OPERATION ........................................................................................... 14
TROUBLESHOOTING AND FAQ ............................................................ 15-19
PARTS LAYOUT .......................................................................................... 20-22
WARRANTY....................................................................................................... 23
Manual

Table of Contents

1205

Advertisement

Table of Contents
loading

Summary of Contents for St. Croix York

  • Page 1: Table Of Contents

    York Insert Operation & Maintenance Manual Table of Contents ST. CROIX FEATURES ..................2 INSTALLATION....................3 PREVENTING CHIMNEY FIRES ..............3 SATISFACTORY PERFORMANCE..............3 Pellet Fuel .......................3 Add Corn to the Mix....................3 OPERATING INSTRUCTIONS................. 3 Control Board Features................4 Thermostat Function – How does it work? ..........5 Pre-Lighting Instructions................6...
  • Page 2 This owner's manual is designed to help you obtain maximum benefit from your St. Croix wood pellet stove. Please read this manual in its entirety BEFORE operating your pellet stove. During the manufacturing process every effort has been expended to ensure that each St.
  • Page 3: St. Croix Features

    45 Lbs. Hopper Digital Tube Control Board Scraper With Diagnostic Features Exclusive Large “SmartStat” Viewing Fully Automatic Glass Auto Ignite With System Wash Versa Grate System System 3 Tray Ash Pan System with Quick Release Latch York Operations Manual Page 2...
  • Page 4: Installation

    Operation and Maintenance York Insert Pellet Stove CAUTION: Operate this unit only with the fuel hopper lid closed. Failure to do so may result in emission of products of combustion from the hopper under certain conditions. Maintain hopper seal in good condition.
  • Page 5: Control Board Features

    This would only be used in the case the ON PAGES 15-19 BEFORE OPERATING THE Stove was hooked up to a tall Vertical Chimney (see STOVE. point 9 on page 18 for more information) York Operations Manual Page 4...
  • Page 6: Thermostat Function - How Does It Work

    SmartStat Mode – How does it work? The SmartStat Function on a St. Croix Pellet stove is the way a St. Croix operates as a Fully Automatic stove. A stove operating as a Fully Automatic stove Figure 2 works great when constant heat isn’t needed.
  • Page 7: Pre-Lighting Instructions

    110 degrees F, the Stove will go setting (See Diagnostic Features in the into “Internal Alarm” and the Auger will quit column to the right). Once the board senses feeding fuel. Once the stove completes the York Operations Manual Page 6...
  • Page 8: Safety Features

    Daily Maintenance unresponsive you must unplug the stove, wait 10 seconds and plug the stove back in to reset the The St. Croix Pellet Stove has been Safety Tested board. by an accredited, independent laboratory. “Internal Alarm”. When the control board...
  • Page 9: Flame Pattern Characteristics

    If you experience problems adjusting the stove grate. This is how the grate continuously cleans during the Break-In Period, contact your dealer. itself. Figure 3 Figure 4 York Operations Manual Page 8...
  • Page 10: Maintaining The Stove

    The Versa Grate System – First, let’s become familiar with the burn system in a St. Croix Pellet NOTE: FAILURE TO KEEP YOUR STOVE stove. The system in the York Insert is a little CLEAN, DESCRIBED THIS different than in the Freestanding models (See Fig 5 MANUAL, COULD RESULT IN POOR below).
  • Page 11: Daily Maintenance

    2. There are 3 separate ash pans (See figure 7) in the as needed. With proper precautions the grate may York insert. Be sure to empty the center ash pan be partially cleaned while the stove is hot. Follow before it is allowed to plug the burn grate. If stove is...
  • Page 12: Periodic Maintenance

    Use of a glass cleaner ONLY permitted 2. Clean the Ash Traps. The York Insert has 2 when the stove is cold. Tip: Dip the damp towel exhaust cleanout covers (see figure 8) located below in the ashes to remove stubborn buildup on the the rear brick panel.
  • Page 13 3. Clean holes in the Grate Weldment and Shaker Plate at least weekly. Remove the burn grate and use a small metal object to clean out plugged holes ( See figure 5 ). Figure 9 York Operations Manual Page 12...
  • Page 14: Yearly Maintenance

    Many dealers offer a Service Contract that around the fan motors. Call your dealer for this will cover needed Periodic and Yearly service. maintenance. Contact your St. Croix dealer for assistance in maintaining your stove in The Exhaust fan should be removed and top condition.
  • Page 15: Safe Operation

    Fall Startup. Prior to lighting the first fire check the outside area around the exhaust and air intake systems for obstructions. Try all controls to see that they are working prior to lighting a York Operations Manual Page 14...
  • Page 16: Troubleshooting And Faq

    If there is fuel in the hopper, check to see if there is an obstruction in the auger system or if the auger set screw is loose. Solution: Remove obstruction and re-light the stove or tighten the setscrew on the auger shaft. York Operations Manual Page 15...
  • Page 17 Check the fuse on the back of the control board. Replace with a 250 Volt, 5 Amp fuse. Part Number 80P20057-R Why is my glass dirty? Normal operation of your St. Croix stove will produce a white/tan build-up on the glass that wipes off with a dry paper towel. However, extended burning on the low setting only, will produce a darker tan color.
  • Page 18 #1 and #4 light at the same time. This will decrease the feed rate by .25 seconds. This is the #1-Low setting, 1.25 seconds. The #1 Low setting will give less heat, but will also cause more build-up to form on the glass. York Operations Manual Page 17...
  • Page 19 9. Why is my glass dirty and how to use the Fan button to help correct it? Normal operation of your St. Croix stove will produce a build-up on the glass that should be wiped off on a daily basis.
  • Page 20 Operations Manual and perform all the maintenance issues covered in the Daily and Periodic Maintenance section of the Manual. If the stove still does not operate correctly call your Dealer for Assistance. York Operations Manual Page 19...
  • Page 21: Parts Layout

    York Parts Layout PART NUMBER DESCRIPTION 80P52893-R ASH LIP/DOOR 80P52897-R SIDE ASHPAN 80P52899-R CENTER ASHPAN 80P52897-R SIDE ASHPAN 80P52901-R LOWER TRIM PANEL 80P52263-R DECORATIVE GRILL - RIGHT 80P52263-R DECORATIVE GRILL - LEFT 80P52677-R IGNITER/HOT ROD 80P21279-R-LWCR BRICK PANEL – RIGHT SIDE...
  • Page 22 York Operations Manual Page 21...
  • Page 23 80P65021-R HINGE PINS – MAIN DOOR 80P53787-R DAMPER CABLE ASSEMBLY CAUTION: The electrical components of the stove are not owner serviceable. Call your dealer for proper diagnosis of electrical problems and service to those components. York Operations Manual Page 22...
  • Page 24: Warranty

    This warranty gives you specific legal rights, and you may have other rights, which vary from state to state. York Operations Manual Page 23...
  • Page 25 Feed Trim: Circle one (See point 5 on page 5) Default Pilot High Pilot Low Pilot Serial Number: Date of Purchase: Dealer Information: Even Temp, Inc. P.O. Box 127 Waco, NE 68460 EMAIL: service@eventempinc.com WEB ADDRESS: www.stcroixheat.com York Operations Manual Page 24...