Mounting the Charger

The charger can be easily mounted onto a secure surface. To mount the
charger, complete the following:
1.
Select a secure location for the charger to be mounted.
2.
Measure a distance of 2.36 in. (60 mm) for the retaining screws.
Refer to Figure 1.
Figure 1. Mounting Bracket
Mounting bracket
1
Philips retaining screws (2)
2
3.
Using the screws provided, mount the bracket.
4.
Attach the charger to the bracket by sliding the charger mounting
ports down onto the mounting bracket. Refer to Figure 2.
Figure 2. Attaching the Charger Base
Charger base
1
Mounting bracket
2
3
Mounting ports
4
Retaining screw holes
5.
Press the charger firmly against the bracket until the release tabs
click.
Charging
a Warning
To charge successfully, the temperature must be between
50°F to 95°F (10°C to 35°C). If the detector emits a low battery
alarm, charge the battery immediately.
When charging a new battery for the first time, fully charge the battery pack
before use (approximately 3.5 hours).
Note
If a fully charged battery is inserted into the charger, the charger
status LED lights red for 6 to 10 minutes and then changes to
green (does not damage the battery).
The detector can remain in the cradle after charging is complete.
Charging the battery pack in temperatures above 86°F (30°C)
greatly reduces the life of the battery pack.
The battery pack may be hot immediately after charging.
Approximately three charges are required to achieve a full charge
capacity for a new battery pack.
Charging the Battery Pack with the Detector
To charge the detector, complete the following:
1.
Insert the power cord into the charger port. Refer to Figure 3.
Figure 3. GasAlertMicro 5/PID/IR Battery Charger (Back)
Back of the charger
1
Power jack port
2
Charger power jack
3
2.
Plug the power cord into a Vac outlet.
The charger performs a self-test. The charger LED lights red then
green during the test. When the self-test is complete, the LED
deactivates.
3.
Deactivate the detector.