NOTICE
For Delta PERFORMANCE applica-
tions that may exceed the 100 feet maxi-
mum allowable equivalent length for the
venting system, contact Triangle Tube
Engineering Department for additional
information on how the appliance can be
adjusted to the application.
Table 2- Allowable Equivalent Length (Combined Vent and Combustion Air)
Maximum
Allowable for Linear
Length Combined
PERFORMANCE
Refer to vent manufacturer's
recommended clearances
Refer to vent
manufacturer's
recommended
clearances
2 Ft.
Max.
S
TriangleTube
Hot Water Specialists
Domestic
Primary
Heating
Temperature/Pressure
Combustion
Air Inlet
Fig. 19: Single Wall Vertical Vent Installation
Total Elbows within the Venting / Combustion Air System
2
180
Rain Cap
Storm
Collar
Adjustable
Flashing
Roof Jack
Support
Firestop
Clamp
Condensate
Drain with
trap loop
To drain
dispose of condensate
according to local codes
Primary
Heating
-
For each elbow included in the system,
the maximum allowable linear length
must be reduced as follows:
• Each 90º elbow within the system is
the equivalent of 10 linear feet.
• Each 45º elbow within the system is
the equivalent of 5 linear feet.
It is recommended that the installer uses the
same number of elbows and length of piping
on the venting system and the combustion air
inlet.
3
4
5
170
160
150
Flexible
Air Hose
Combustion
Air Inlet
Fig. 20: Concentric Vertical Vent Installation
35
6
7
140
130
Rain Cap
Vertical
Termination
Adapter
5" Storm
Collar
Tall Cone
Flashing
Fire Stop/Support
Appliance
Hose
Adapter
Clamps
Condensate
Spring
Drain Hose
Clip
3" Diameter
Trap Loop
Flue
Outlet
TriangleTube
Hot Water Specialists
Domestic
Primary
Primary
Heating
Temperature/Pressure
Heating
Cable Ties