Alignment
Only one extender board (if optional)
should be installed at a time for access to the
board being aligned. Also, the test equipment
must be thoroughly warmed up before begin-
ning.
Note: Signal levels in dB referred to in
alignment are based on 0 dBp=0.5pV.
Table note: DC voltages should be within
Local Unit
(1) Ref erence Oscillator
Connect the frequency counter to TP2005.
If the TCXO is installed, tonfirm 10.485760
MHz &5 Hz on the counter.
(2) 2nd Local Oscillator
Connect a 50-$2 resistor in parallel with the
frequency counter across the socket J2011.
counter.
0
Replace the counter with the RF millivoltme-
ter, and tonfirm at least 45 mVrms.
0
Connect the RF millivoltmeter to TMOOl, and
(3) vco
2
0 Tune the receiver to 3.999 MHz and select
USB mode.
0 Connect the DC Voltmeter to TP2002 (while
adjusting VCOs, connect the DC Voltmeter to
TP2002)
0 Adjust L2003 for 7.0 & 0.1 V.
Frequency
(MHz)
0.050
vco3
0 Tune the receiver to 14.499 MHz in USB
0 Adjust L2005 for 7.0 V ti.l V.
0 Tune the receiver to 8.00 MHz, and tonfirm
v c o 4
0
0
v c o 5
0 Tune the receiver to 30.000 MHz in USB
Main Unit
(1) 2nd Local Amplifier
0 Adjust Tl003 on the local unit for maximum
(2) IF Werstage Transformer
0
0
0
0
Volts DC
0.9 - 1.4
(3) IF Gain
mode.
1.1 to 1.6 V on the meter.
Tune the receiver to 21.999 MHz in USB
mode.
Tune the receiver to 14.500 MHz, and tonfirm
0.8 to 1.3 Volts on the meter.
mode.
1.4 to 1.9 V on the meter.
(at least '500 mV) on the meter.
and select FM mode.
Connect the RF Signal generator to the an-
tenna jack, and inject an 80 dBp Signal at
14.200 MHz.
Turn the modulation switch (of the Signal
generator) Off, and inject an 80 dBp Signal at
14.200 MHz.
succession several times for peak S-meter in-

Advertisement