Updating The Op500; Option Programming Tables - CompuSTAR CM4200DX Install Manual

Table of Contents

Advertisement

To change the option number you wish to program, use the left and right arrow keys on the OP-500, it will
scroll through the options available in menu 1 and then move to menu 2, then 3 and 4. At the end of menu 4, if
you have turned on diesel mode or the channel expander, or set any of the auxiliary outputs to "Program", you
will have the option to program the duration of the diesel timer and/or auxiliary outputs. After the aux and
diesel settings (if selected), the POC options will be displayed. The "POCs" are the programmable outputs on
CN3 of the Pro-Series modules.
You can then use the up and down arrow buttons to adjust the option's settings. "1" is the default setting, and
"2", "3", and "4" are the optional settings. The timing of the aux outputs and of the diesel timer is displayed in
seconds, and the POCs can be set between 0 (default) and 12. If you wish to restore all of the factory defaults,
you can press "R" and "W" until the OP-500 chirps.
3. Finalizing Option Settings to Control Module
When you are done adjusting the various option settings or resetting them to the factory defaults, press and hold
the "W" (write) button until the OP-500 chirps. This will write the settings to the control module. Wait until the
module displays "Success" before disconnecting it from the antenna cable.
Updating the OP-500
This is required only if you have an early version of the Option Programmer OP-500.
1. To retrieve software for updating please email: support@compustar.com. Please write "request for update
software" in subject. You can also go to
2. You will need to first identify what COM port your USB device is set up to use. To do this, Right-click on
"My Computer" and go to "Properties". Once the properties window is on the screen, click the "Hardware" tap
at the top of the window. Then in the main body of the window, click on the Device Manager" button. Under
"Ports (COM & LPT)" There should be a device called "USB Serial Port (COM?)", The number that is in
place of the question mark is your selected com port.
3. Connect the USB Updater to the computer, do not have anything (iDataLink, CM4000, OP500 etc) connected
to the updater when connecting it to the computer. After a few seconds, connect the USB Updater to the "USB"
port on the OP500 using the supplied cable. Open the "OP500 v6.2" folder and hold the "W" button on the
OP500 down while you double-click the file that matches your com port.
Example: I use COM5 so I would use "UPDATE-V6-COM5.bat". Once the OP500 displays "UP" on the screen,
you can let go of the "W" button. After it is finished, just disconnect the OP500 from the USB Updater and
connect the next OP500 if you have more to do.
________________________________________________________________________________________________
O
P
PTION
ROGRAMMING
Note: Option Programming, RPS Programming and Secure Valet Programming are available only when the system is
disarmed/unlocked.
Special Option Group #1 and #2 can only be programmed with the Option Programmer OP500.
OPTION GROUP 1
Feature
1-1
1-2
1-3
1-4
1-5
1-6
www.compustar.com
T
ABLES
Default(I)
Off
0.8 sec
Off
Off
After Start Shutdown and
After Start Shutdown and
First Lock
Locks When Reservation
Mode is Set
Setting
Optional(II)
Optional(III)
Lock After Remote Start
On
Only
2.5 sec
0.125 sec
On
On
Every Lock
Does Not Lock When
Reservation Sets 10 Seconds
Reservation is Set
After the Last Door is Closed
14
Applicable To
Optional(IV)
CM4000
CM4200-DX
V
3.5 sec
V
V
V
V
V
CM4300
V
V
V
V
V
V
V
V
V
V

Advertisement

Table of Contents
loading

Table of Contents