3.03 Drilling Template (Top Flue Application)
1.
CH flow
2.

Safety Valve

3.

Domestic hot water outlet

4.
Gas supply
5.

Domestic hot water inlet

6.
CH return
14
DOMINA N 80
Fig. 15a
Ø3/4"
Ø1/2"
Ø1/2"
1
2
3
Select suitable mounting position
boiler, using the template mark flue outlet
and boiler mounting points. Drill two
10mm holes 90mm deep to accept the
wall plugs, fit wall plugs. Fit two special
wall plugs on the wall as described in the
fig. 14a. Fasten the wall bracket to the
wall using an antitheft nut on the right
side and a standard nut (M8) on the left
side. Mount the boiler on the wall bracket
and fix using an antitheft nut on the
left side and a standard nut (M8) on the
right side. Using a core drill cut a 118mm
diameter hole for the flue.
Ø118
269
200
150 min
21 min
Ø1/2"
Ø1/2"
Ø3/4"
4
5
6
for
0
1 1
5 min
Fig. 15b