Wall mounted, room sealed, fan assisted, gas combination boiler
Hide thumbs Also See for optima 801:

Advertisement

801
04/98
WALL MOUNTED, ROOM SEALED,
FAN ASSISTED, GAS COMBINATION BOILER
USERS
INSTRUCTIONS
Read these Instructions thoroughly
before using the appliance
FERROLI HELPLINE
Phone numbers:
FOR SERVICE INFORMATION OR
HELP TELEPHONE: 0121 3523500
Installer
ALWAYS QUOTE YOUR SERIAL NUMBER
FOR IMMEDIATE ASSISTANCE
Service Engineer
Serial No.
G.C. NO: 47-267-17
ALL SPECIFICATIONS SUBJECT TO CHANGE
Stockton Close, Minworth Industrial Park, Minworth, Sutton Coldfield, West Midlands B76 8DH
Tel.: 0121/3523500 - Fax 0121/3523510

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the optima 801 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ferroli optima 801

  • Page 1 WALL MOUNTED, ROOM SEALED, FAN ASSISTED, GAS COMBINATION BOILER USERS INSTRUCTIONS Read these Instructions thoroughly before using the appliance FERROLI HELPLINE Phone numbers: FOR SERVICE INFORMATION OR HELP TELEPHONE: 0121 3523500 Installer ALWAYS QUOTE YOUR SERIAL NUMBER FOR IMMEDIATE ASSISTANCE Service Engineer Serial No.
  • Page 3 Conditions of Installation GAS SUPPLY It is the law that all gas appliances are installed and serviced by a competent person in accordance with the Gas Safety Regulations (Installation & Use) 1994, and the manufacturers instructions. Failure to observe these requirement may lead to prosecution. ELECTRICAL SUPPLY 230 V ~ 50 Hz FUSED 3A.
  • Page 4 Boiler Lighting Instructions Flame viewing opening Important: Control system has a built in waiting time for Central Heating. A max. 3 minutes delay following shut down of Boilerstat, Clock, Roomstat or use of Hot Water is normal. C.H. pressure C.H. boiler gauge thermostat AUTO...
  • Page 5 To Shut Down The Boiler For Long Periods Turn off the electricity supply. Boiler Controls CENTRAL HEATING SELECTOR SWITCH The central heating selector switch has three positions, these are: Heating Timed & Hot Water For domestic hot water supply and central heating controlled by the time clock. Hot Water For domestic hot water supply only.
  • Page 6 VENTILATION If the appliance is installed in a compartment or cupboard, do not obstruct any purpose provided ventilation openings. Do not use the compartment or cupboard for storage purposes. FROST PROTECTION Note - The boiler has its own built-in frost protection which automatically fire the boiler in low temperature situations irrespective of the selector switch setting.
  • Page 7 To set time of day Slide switch (A) to left position Using button + and - adjust until the correct time is shown on display (B). Pre Set Programmes. The timer is pre programmed with 3 ON and 3 OFF times. 6:30 - 8:30 If these are suitable no programming is required and the slide switch (A) can be 12:00 - 12:00...
  • Page 8 IMPORTANT: If the pump sticks, it can usually be freed by removing the chrome center screw, (a small amount of water will escape) and manually free the impeller using a screwdriver in the end of the shaft. Phone numbers: Installer Service Engineer BECAUSE OF OUR CONSTANT ENDEAVOUR FOR IMPROVEMENT DETAILS MAY VARY SLIGHTLY FROM THOSE QUOTED IN THESE INSTRUCTIONS.