Fault Codes - Toro Greensmaster TriFlex 3320/3420 Service Manual

Ride-on lawnmowers
Table of Contents

Advertisement

Fault Codes

The list below identifies the fault codes that are gener-
ated by the TEC controller to identify an electrical sys-
tem malfunction (fault) that occurred during machine
operation. On machines with serial number below
312000000, the fault code will be retrieved using the
diagnostic light (see Diagnostic Light (Serial Number
Below 312000000) in this section). Use the InfoCenter
Display for fault retrieval on machines with serial num-
ber above 312000000 (see InfoCenter Display (Serial
Number Above 312000000) in this chapter).
Fault Code (Lamp Flashes)
1 -- 1
1 -- 2
1 -- 3
1 -- 4
1 -- 5
1 -- 6
1 -- 7
1 -- 8
1 -- 9
2 -- 1
2 -- 2
2 -- 3
2 -- 4
2 -- 5
2 -- 6
2 -- 9
3 -- 1
3 -- 2
3 -- 3
3 -- 4
3 -- 5
3 -- 6
3 -- 7
3 -- 9
4 -- 1
Electrical System
The reel speed POT reading is out of range indicating either an open or short
Generator controller identified a fault associated with control of the
High Temp Warning -- #1 cutting unit (allow machine to cool down) (Note: this
fault IS NOT caused by a faulty sensor)
High Temp Warning -- #2 cutting unit (allow machine to cool down) (Note: this
fault IS NOT caused by a faulty sensor)
High Temp Warning -- #3 cutting unit (allow machine to cool down) (Note: this
fault IS NOT caused by a faulty sensor)
High Temp Warning -- generator (allow machine to cool down) (Note: this fault
IS NOT caused by a faulty sensor)
#1 cutting unit motor at zero (0) RPM for more than three (3) seconds (insuffi-
cient torque is available to rotate motor)
#2 cutting unit motor at zero (0) RPM for more than three (3) seconds (insuffi-
cient torque is available to rotate motor)
#3 cutting unit motor at zero (0) RPM for more than three (3) seconds (insuffi-
cient torque is available to rotate motor)
The master controller does not recognize the model number
All four (4) individual slaves (generator and all cutting unit motors) are offline on
#1 cutting unit motor is offline on the CAN--Bus network
#2 cutting unit motor is offline on the CAN--Bus network
#3 cutting unit motor is offline on the CAN--Bus network
Generator is offline on the CAN--Bus network
Excessive engine temperature has caused engine shutdown
System voltage to #1 cutting unit motor is insufficient (motor will be disabled)
System voltage to #2 cutting unit motor is insufficient (motor will be disabled)
System voltage to #3 cutting unit motor is insufficient (motor will be disabled)
System voltage to generator is insufficient
Initial 48V system voltage is incorrect
Page 6 - - 22
Fault Description
48V contactor
the CAN--Bus network
TEC controller is faulty
Coolant sensor is faulty
Current to fan relay is excessive
TEC controller is faulty
Greensmaster 3320/3420