How To Mount Installation Plate

The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline. It is also important to use caution concerning the
location of the installation plate-routing of the wiring to power outlets is through the walls typically.
Drilling the hole through the wall for piping connections must be done safely.
CHASSIS
(Grade)
A
S4
50
SE
65
S5
95

Drill a Hole In The Wall

• Drill the piping hole with a ø70mm(2.76in)
hole core drill. Drill the piping hole at either
the right or the left with the hole slightly
slanted to the outdoor side.
Distance (mm)
B
C
D
105
59
105
110
85
110
122
235
122
Chassis
Hook
Installation plate
D
C
Ø70mm
Left rear piping
Indoor
Installation
Installation Plate
Type "A"
B
A
Ø70mm
Right rear piping
WALL
Outdoor
Installation Manual 15