Fixing Installation Plate
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using Horizontal meter
.
2. Measure the wall and mark the centerline. It is also important to use caution concerning the
location of the installation plate. Routing of the wiring to power outlets is through the walls
typically. Drilling the hole through the wall for piping connections must be done safely.
Unit Outline
Ø70(2.76)
Left rear piping
133(5.2)
175(6.9)
Drill a Hole in the Wall
• Drill the piping hole with a ø70mm(2.76in)
hole core drill. Drill the piping hole at either
the right or the left with the hole slightly
slanted to the outdoor side.
Chassis
Place a level on raised tab
442(17.4)
Installation Plate
Installation Plate
Hook
442(17.4)
95(3.7)
217(8.5)
[Unit : mm(inch)]
WALL
Indoor
Installation Manual 11
Indoor unit
Type "A" Screws
Ø70(2.76)
Ø70(2.76)
Right rear piping
Outdoor