Time Format
Date Format: Sets the format preferences for date (MM/DD/YYYY or DD/MM/YYYY).
Time Format: Sets the format preferences for time (12h or 24h).
Sync Time: Synchronizes the time displayed on the Thermostat with the Control4 Controller.
Synchronization automatically occurs daily.
Network
Displays nformational boxes that provide ZigBee networking information (MAC and Firmware
Version).
Select Apply to... to apply the current properties to the selected Wireless Thermostats.
Advanced Device Configuration
Temperature Calibration: Allows calibration of the Thermostat's reported temperature by +/- 5
degrees. Example: If the Thermostat reads 72 degrees Fahrenheit, and the current temperature
is determined to be 70 degrees Fahrenheit, press the down button two (2) times to lower the
Thermostat reading to 70 degrees Fahrenheit. Select Set Calibration to confirm the change.
NOTE: No changes to calibration should be made within 20 minutes of powering on
the Thermostat. The Thermostat generates a small amount of heat which affects the
calibration. After 20 minutes of continuous operation, this will stabilize allowing
proper calibration.
Heating Cutoff Point: Sets the temperature for the heating system to turn off past the setpoint.
To adjust, use the up and down arrows, and then press Set Heat Cutoff to confirm the change.
Example: If the Heat Point is set to 68 degrees Fahrenheit, and the Heating Cutoff Point is set
13